Carrier Air Conditioner: Hissing from the outdoor unit after it shuts off
Hissing from the outdoor unit after it shuts off on a Carrier air conditioner: On the Infinity 19VS (24VNA9) a hiss is heard at the outdoor unit for a short time after the compressor stops. This is normally the pressure equalizer valve balancing pressures across the rotary compressor so the next start is easier.
Applies to: Carrier Infinity 19VS variable speed air conditioner 24VNA9
Common causes of hissing from the outdoor unit after it shuts off
- Normal pressure equalizer valve operation during the off cycle
How to fix hissing from the outdoor unit after it shuts off: step by step
- Confirm the hiss happens right after the compressor stops and fades away on its own.
- Explain to the homeowner that this is a normal sound for this unit, to avoid a callback.
- If the hiss is constant while running, or the system has low capacity or icing, check for a refrigerant leak and check pressures instead - that is not the equalizer valve.
If the unit shows an error code, look it up: Carrier Air Conditioner codes
Models
Carrier 2-stage 24ANB/25HNB
24ANB12424ANB13624ANB14824ANB16024ANB72424ANB73624ANB74824ANB760
Carrier Infinity 19VS 24VNA9
24VNA924VNA91324VNA92424VNA92524VNA93624VNA93724VNA94824VNA94924VNA960
Source: Carrier Infinity 19VS Variable Speed Air Conditioner 24VNA9 Application Guideline, catalog 24VNA9---01AG (05/16), Sound section, p.5. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.