Rheem Error Code 06: Compressor open start circuit (Heat Pump)
Rheem error code 06 on a heat pump means: Compressor open start circuit. It is also called Rheem diagnostic code 06.
Homeowner? What Rheem code 06 means for you
Call a technician Your heat pump is reporting: Compressor open start circuit. The heat pump has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.
Safe things you can check yourself
- Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
- Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
- Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
- In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
- Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.
Call (647) 657-2977Book a service call
Licensed technicians serving Vaughan, Toronto and the GTA.
What does Rheem error code 06 mean?
The ICC sees current in the run circuit but none in the start circuit. If this happens four (4) times in one compressor call the ICC locks out with L6. Reported as 6 flashes on the L terminal.
Applies to: (-)PRL-JEC 2-stage 16 SEER heat pumps: RPRL/UPRL-024JEC, -036JEC, -048JEC, -060JEC
Common causes of Rheem code 06
- Damaged, wrong or miswired run capacitor
- Broken wire or loose connector in the start circuit
- Open start winding
Rheem models that use code 06
RPRL-024JECRPRL-036JECRPRL-048JECRPRL-060JEC
Other Rheem Heat Pump codes
All Rheem Heat Pump error codes →
Rheem code 06: homeowner questions
What does Rheem code 06 mean?
Compressor open start circuit. The ICC sees current in the run circuit but none in the start circuit. If this happens four (4) times in one compressor call the ICC locks out with L6. Reported as 6 flashes on the L terminal.
Is it safe to keep using my heat pump with code 06?
It depends on the cause. The heat pump has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.
Can I reset Rheem code 06 myself?
You can try one reset (power off for 30 seconds, then on). If Rheem code 06 comes back, the cause is still there and a licensed technician should check it.
Who can fix Rheem code 06 near me?
Aurora Star Tech Inc. repairs Rheem heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.
Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air
Troubleshooting guides
- Heat pump will not defrost / incomplete or excessive defrost Rheem · Heat Pump
- Insufficient cooling / pressure problems Rheem · Heat Pump
- Outdoor fan runs but compressor does not Rheem · Heat Pump
- Outdoor unit will not run Rheem · Heat Pump
Source: Rheem (-)PRL-JEC Heat Pump Installation Instructions, 12.6 ICC Diagnostic Codes, p.29. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.