Lennox Error Code E205: Gas valve relay contact shorted (Furnace)

Updated · by Aurora Star Tech Inc.

Lennox error code E205 on a furnace means: Gas valve relay contact shorted. It is also called Lennox diagnostic code E205.

Critical severityFurnaceEL296UHV · Lennox SL280UHV · Lennox SL297NV

Homeowner? What Lennox code E205 means for you

Stop and call Your furnace is reporting: Gas valve relay contact shorted. This code is a safety shutdown. Turn the furnace off and call a licensed technician. Do not keep resetting it. If you smell gas, leave the house and call your gas utility or 911 from outside.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Lennox error code E205 mean?

The control's gas valve relay contacts are shorted.

Applies to: EL296UHV(X) series furnaces (integrated control 103130-XX and 107045-XX)

Common causes of Lennox code E205

  • Wiring short at control or gas valve
  • Failed control relay
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Lennox models that use code E205

Show all 22 models

EL296UH045XV36BEL296UH070XV36BEL296UH090XV36CEL296UH090XV48CEL296UH090XV60CEL296UH110XV48CEL296UH110XV60CEL296UH135XV60DSL280UH060NV36ASL280UH070V36ASL280UH080NV48BSL280UH080NV60CSL280UH090V36BSL280UH090V48BSL280UH090V60CSL280UH100NV60CSL280UH110V60CSL280UH135V60DSL297UH040NV36BSL297UH060NV36BSL297UH080NV48CSL297UH080NV60C

Other Lennox Furnace codes

CodeMeaning
E180Outdoor air temperature sensor failure
E200Flame rollout - hard lockout
E201Indoor blower communication failure
E202Blower motor mismatch
E203Unit capacity not programmed
E204Gas valve miswired
E206Gas valve second-stage relay failure
E207Hot surface ignitor open
E223Low pressure switch failed open
E224Low pressure switch failed closed
E225High pressure switch failed open
E226High pressure switch failed closed

All Lennox Furnace error codes →

Lennox code E205: homeowner questions

What does Lennox code E205 mean?

Gas valve relay contact shorted. The control's gas valve relay contacts are shorted.

Is it safe to keep using my furnace with code E205?

No. Code E205 is a safety shutdown, so keep the furnace off until a licensed technician has checked it.

Can I reset Lennox code E205 myself?

Do not keep resetting it. Repeated resets can hide a safety problem; a licensed technician needs to find the cause.

Who can fix Lennox code E205 near me?

Aurora Star Tech Inc. repairs Lennox furnaces in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Furnace Not Turning On: What to Check · Furnace Blinking Light: What the Flash Codes Mean

Troubleshooting guides

Source: Lennox EL296UHV(X) Unit Information / Service Literature, Table 5 Ignition Control 103130-XX Diagnostic Codes, p.34; Ignition Control 107045-XX Diagnostic Codes table, p.41. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.