Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Rinnai Error Code 140: Overheat switch tripped (heat exchanger overheating) (Combi Boiler)

Updated · by Aurora Star Tech Inc.

Rinnai error code 140 on a combi boiler means: Overheat switch tripped (heat exchanger overheating). It is also called Rinnai diagnostic code 140.

Critical severityCombi BoilerI-Series Plus 150K and smaller · I-Series Plus 175K and higher

Homeowner? What Rinnai code 140 means for you

Stop and call Your combi boiler is reporting: Overheat switch tripped (heat exchanger overheating). This code is a safety shutdown. Turn the combi boiler off and call a licensed technician. Do not keep resetting it. If you smell gas, leave the house and call your gas utility or 911 from outside.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Rinnai error code 140 mean?

The bi-metal overheat switch on the right side of the heat exchanger has opened, indicating overheating. It self-resets once cool but will keep tripping until the root cause is fixed.

Applies to: I-Series Plus boilers — 150K BTU and smaller and 175K BTU and higher (Combi and Solo)

Common causes of Rinnai code 140

  • Air in the system (incomplete deaeration)
  • Boiler pump not running, miswired, reversed or seized; blown fuse
  • Closed valves, frozen CH circuit or indirect tank pump issue

A technician checks these and 4 other possible causes on site before replacing any part.

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Rinnai models that use code 140

IP060160CIP090099CIP090160CIP090199CIP120199CIP150199CIP175199CIP199199C

Other Rinnai Combi Boiler codes

CodeMeaning
021DHW continuous operation time exceeded
100Air intake/exhaust blockage or full condensate trap
110Ignition failure
120Flame failure (flame lost during operation)
150Venturi control fault
161High DHW outgoing water temperature
170Venturi blockage / position mismatch
180Gas valve air/fuel adjustment limit reached
190Electrical grounding / short in DC circuit
210Data transfer error
220Gas valve position not detected (reed switch)
250Condensate pump switch tripped (accessory)

All Rinnai Combi Boiler error codes →

Rinnai code 140: homeowner questions

What does Rinnai code 140 mean?

Overheat switch tripped (heat exchanger overheating). The bi-metal overheat switch on the right side of the heat exchanger has opened, indicating overheating. It self-resets once cool but will keep tripping until the root cause is fixed.

Is it safe to keep using my combi boiler with code 140?

No. Code 140 is a safety shutdown, so keep the combi boiler off until a licensed technician has checked it.

Can I reset Rinnai code 140 myself?

Do not keep resetting it. Repeated resets can hide a safety problem; a licensed technician needs to find the cause.

Who can fix Rinnai code 140 near me?

Aurora Star Tech Inc. repairs Rinnai combi boilers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Tankless Water Heater No Hot Water: What to Check · Boiler Not Heating: What to Check

Troubleshooting guides

Source: Rinnai Troubleshooting I-Series Plus Boiler Diagnostic Codes (800000375), p.9. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service