Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Daikin Error Code H9: H9 subcode 02: heat source X18A thermistor disconnected (Water Heater)

Updated · by Aurora Star Tech Inc.

Daikin error code H9 on a water heater means: H9 subcode 02: heat source X18A thermistor disconnected. It is also called Daikin diagnostic code H9.

Medium severityWater HeaterMega-Q

Homeowner? What Daikin code H9 means for you

Check, then call Your heating or cooling system is reporting: H9 subcode 02: heat source X18A thermistor disconnected. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Daikin error code H9 mean?

X18A thermistor connector on heat source board (A1P) is disconnected.

Applies to: Heat source unit

Common causes of Daikin code H9

  • X18A thermistor connector loose or unplugged
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Other Daikin Water Heater codes

CodeMeaning
A6Water not flowing in cascade unit
E3E3 subcode 01: cascade unit HPS connector unplugged
E4E4 subcode 02: heat source unit low refrigerant or stop valve closed
E9E9 subcode 01: cascade unit X23A valve coil connector unplugged
ECLow tank water temperature
F3F3 subcode 01: cascade unit low refrigerant
HJFlow rate cannot be adjusted (cascade)
J3J3 subcodes 16 to 19: cascade unit X29A thermistor disconnected
J5J5 subcode 03: heat source X30A thermistor disconnected
J6J6 subcode 02
J7J7 subcodes 13 and 14: cascade unit X30A thermistor disconnected
J8J8 subcode 02

All Daikin Water Heater error codes →

Daikin code H9: homeowner questions

What does Daikin code H9 mean?

H9 subcode 02: heat source X18A thermistor disconnected. X18A thermistor connector on heat source board (A1P) is disconnected.

Is it safe to keep using my heating or cooling system with code H9?

It depends on the cause. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Can I reset Daikin code H9 myself?

You can try one reset (power off for 30 seconds, then on). If Daikin code H9 comes back, the cause is still there and a licensed technician should check it.

Who can fix Daikin code H9 near me?

Aurora Star Tech Inc. repairs Daikin heating or cooling systems in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Troubleshooting guides

Source: Mega-Q installation manual, p. 48. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.