Daikin Error Code 80: Thermistor connector X17A disconnected (cascade) (Water Heater)

Updated · by Aurora Star Tech Inc.

Daikin error code 80 on a water heater means: Thermistor connector X17A disconnected (cascade). It is also called Daikin diagnostic code 80.

Medium severityWater HeaterMega-Q

Homeowner? What Daikin code 80 means for you

Check, then call Your heating or cooling system is reporting: Thermistor connector X17A disconnected (cascade). This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Daikin error code 80 mean?

Cascade unit: the X17A thermistor connector on A6P is disconnected.

Applies to: Cascade unit

Common causes of Daikin code 80

  • X17A connector disconnected
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Other Daikin Water Heater codes

CodeMeaning
42Connector X3A disconnected (cascade)
81Thermistor connector X18A disconnected (cascade)
A6Water not flowing in cascade unit
E3E3 subcode 01: cascade unit HPS connector unplugged
E4E4 subcode 02: heat source unit low refrigerant or stop valve closed
E9E9 subcode 01: cascade unit X23A valve coil connector unplugged
ECLow tank water temperature
F3F3 subcode 01: cascade unit low refrigerant
H9H9 subcode 02: heat source X18A thermistor disconnected
HJFlow rate cannot be adjusted (cascade)
J3J3 subcodes 16 to 19: cascade unit X29A thermistor disconnected
J5J5 subcode 03: heat source X30A thermistor disconnected

All Daikin Water Heater error codes →

Daikin code 80: homeowner questions

What does Daikin code 80 mean?

Thermistor connector X17A disconnected (cascade). Cascade unit: the X17A thermistor connector on A6P is disconnected.

Is it safe to keep using my heating or cooling system with code 80?

It depends on the cause. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Can I reset Daikin code 80 myself?

You can try one reset (power off for 30 seconds, then on). If Daikin code 80 comes back, the cause is still there and a licensed technician should check it.

Who can fix Daikin code 80 near me?

Aurora Star Tech Inc. repairs Daikin heating or cooling systems in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Troubleshooting guides

Source: Daikin Mega-Q installation manual, p. 50. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.