Daikin Error Code H6: Position sensor abnormality (compressor start-up failure) (Heat Pump)

Updated · by Aurora Star Tech Inc.

Daikin error code H6 on a heat pump means: Position sensor abnormality (compressor start-up failure). It is also called Daikin diagnostic code H6.

High severityHeat PumpFTXM-W/V

Homeowner? What Daikin code H6 means for you

Call a technician Your heat pump is reporting: Position sensor abnormality (compressor start-up failure). The heat pump has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Daikin error code H6 mean?

A compressor start-up failure is detected by checking compressor running through the position detection circuit. If the error repeats, the system shuts down. Reset occurs after about 11 minutes of continuous running with no other error.

Applies to: FTXM-W/V outdoor unit, compressor start-up

Common causes of Daikin code H6

  • Power supply voltage out of specification
  • Disconnected compressor harness
  • Defective compressor

A technician checks these and 3 other possible causes on site before replacing any part.

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Other Daikin Heat Pump codes

CodeMeaning
Green LED: Rapid flashingGreen LED rapid flashing, normal network traffic
Green LED: Solid onGreen LED solid, terminal 1 / terminal 2 miswire
Green Rx LED 1 steady flashNetwork: no network found
Green Rx LED offNetwork: no power or no communication
Green Rx LED on solidNetwork: terminal 1 / 2 miswired
H0Compressor system sensor abnormality
H8DC voltage/current sensor abnormality
Red comm LED 1 flashNetwork: communications failure
Red comm LED 2 flashesNetwork: out-of-box reset
Red LED: 1 flashRed LED 1 flash, communications failure
Red LED: 2 flashRed LED 2 flash, out-of-box reset
Red LED: OffRed communications LED off

All Daikin Heat Pump error codes →

Daikin code H6: homeowner questions

What does Daikin code H6 mean?

Position sensor abnormality (compressor start-up failure). A compressor start-up failure is detected by checking compressor running through the position detection circuit. If the error repeats, the system shuts down. Reset occurs after about 11 minutes of continuous running with no other error.

Is it safe to keep using my heat pump with code H6?

It depends on the cause. The heat pump has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset Daikin code H6 myself?

You can try one reset (power off for 30 seconds, then on). If Daikin code H6 comes back, the cause is still there and a licensed technician should check it.

Who can fix Daikin code H6 near me?

Aurora Star Tech Inc. repairs Daikin heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: SiUS042113EA service manual, p. 133-134. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.