Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Daikin Error Code H0: Compressor system sensor abnormality (Heat Pump)

Updated · by Aurora Star Tech Inc.

Daikin error code H0 on a heat pump means: Compressor system sensor abnormality. It is also called Daikin diagnostic code H0.

Medium severityHeat PumpFTXM-W/V

Homeowner? What Daikin code H0 means for you

Check, then call Your heat pump is reporting: Compressor system sensor abnormality. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Daikin error code H0 mean?

The system checks the DC current before compressor start. Fault is declared when the converted voltage is outside 0.5 to 4.5 V, or when the DC voltage before start is below 50 V.

Applies to: FTXM-W/V outdoor unit, compressor start

Common causes of Daikin code H0

  • Broken or disconnected harness
  • Defective outdoor unit PCB
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Other Daikin Heat Pump codes

CodeMeaning
Green LED: OffGreen receive LED off
Green LED: Rapid flashingGreen LED rapid flashing, normal network traffic
Green LED: Solid onGreen LED solid, terminal 1 / terminal 2 miswire
Green Rx LED 1 steady flashNetwork: no network found
Green Rx LED offNetwork: no power or no communication
Green Rx LED on solidNetwork: terminal 1 / 2 miswired
H6Position sensor abnormality (compressor start-up failure)
H8DC voltage/current sensor abnormality
Red comm LED 1 flashNetwork: communications failure
Red comm LED 2 flashesNetwork: out-of-box reset
Red LED: 1 flashRed LED 1 flash, communications failure
Red LED: 2 flashRed LED 2 flash, out-of-box reset

All Daikin Heat Pump error codes →

Daikin code H0: homeowner questions

What does Daikin code H0 mean?

Compressor system sensor abnormality. The system checks the DC current before compressor start. Fault is declared when the converted voltage is outside 0.5 to 4.5 V, or when the DC voltage before start is below 50 V.

Is it safe to keep using my heat pump with code H0?

It depends on the cause. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Can I reset Daikin code H0 myself?

You can try one reset (power off for 30 seconds, then on). If Daikin code H0 comes back, the cause is still there and a licensed technician should check it.

Who can fix Daikin code H0 near me?

Aurora Star Tech Inc. repairs Daikin heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: SiUS042113EA service manual, p. 132. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.