Updated · by Aurora Star Tech Inc.

Daikin error code C4 on a heat pump means: Indoor heat exchanger thermistor abnormality. It is also called Daikin diagnostic code C4.

Medium severityHeat PumpFTXM-W/V

Homeowner? What Daikin code C4 means for you

Check, then call Your heat pump is reporting: Indoor heat exchanger thermistor abnormality. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Daikin error code C4 mean?

The voltage across the indoor heat exchanger thermistor is outside the valid range (too high or too low) with power on. The thermistor circuit is considered faulty.

Applies to: FTXM-W/V wall mounted inverter heat pump, indoor unit

Common causes of Daikin code C4

  • Disconnected connector
  • Faulty thermistor
  • Faulty indoor unit PCB
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Other Daikin Heat Pump codes

CodeMeaning
55Repeated high discharge temperature faults (minor)
57Sweating on the board cooling loop
76Indoor-outdoor, gas furnace or blower communication error (during operation)
77Indoor unit - thermostat communication error (start-up and during operation)
78Indoor unit - outdoor unit, gas furnace or blower unit communication error (startup operation)
A6Indoor fan motor (DC motor) abnormality
C9Room temperature sensor / humidity sensor abnormality (communication or malfunction)
CCHumidity sensor abnormality (communication or malfunction)
CoreSense 1CoreSense: yellow 1 flash, long run time
CoreSense 2CoreSense: 2 flashes, pressure trip (yellow alert / red lock)
CoreSense 3CoreSense: 3 flashes, short cycling (yellow alert / red lock)
CoreSense 4CoreSense: 4 flashes, locked rotor (yellow alert / red lock)

All Daikin Heat Pump error codes →

Daikin code C4: homeowner questions

What does Daikin code C4 mean?

Indoor heat exchanger thermistor abnormality. The voltage across the indoor heat exchanger thermistor is outside the valid range (too high or too low) with power on. The thermistor circuit is considered faulty.

Is it safe to keep using my heat pump with code C4?

It depends on the cause. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Can I reset Daikin code C4 myself?

You can try one reset (power off for 30 seconds, then on). If Daikin code C4 comes back, the cause is still there and a licensed technician should check it.

Who can fix Daikin code C4 near me?

Aurora Star Tech Inc. repairs Daikin heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: SiUS042113EA service manual, p. 107. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.