Daikin Error Code b4: Blower motor current trip or lost rotor (Air Handler)

Updated · by Aurora Star Tech Inc.

Daikin error code b4 on a air handler means: Blower motor current trip or lost rotor. It is also called Daikin diagnostic code b4.

Medium severityAir HandlerDV / DFVE

Homeowner? What Daikin code b4 means for you

Check, then call Your air handler is reporting: Blower motor current trip or lost rotor. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Daikin error code b4 mean?

The blower motor reports a current trip or lost rotor through its control status flags.

Applies to: EEV air handler

Common causes of Daikin code b4

  • Fan or motor obstructed
  • Filters blocked
  • Blockage in ductwork

A technician checks these and 1 other possible causes on site before replacing any part.

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Other Daikin Air Handler codes

CodeMeaning
73Liquid side thermistor abnormality
74Gas side thermistor abnormality
75Pressure sensor abnormality
76Indoor unit to outdoor unit / gas furnace / blower communication error (during operation)
77Indoor unit to thermostat communication error (start-up and during operation)
78Indoor unit to outdoor unit / gas furnace / blower communication error (start-up operation)
b7ID blower motor missing required parameters, fails to start
b9Low indoor airflow (without electric heat)
E76No outdoor unit or indoor unit communication
E77No thermostat communication
E78No outdoor unit or indoor unit communication
Eb0Estimated indoor airflow near zero CFM

All Daikin Air Handler error codes →

Daikin code b4: homeowner questions

What does Daikin code b4 mean?

Blower motor current trip or lost rotor. The blower motor reports a current trip or lost rotor through its control status flags.

Is it safe to keep using my air handler with code b4?

It depends on the cause. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Can I reset Daikin code b4 myself?

You can try one reset (power off for 30 seconds, then on). If Daikin code b4 comes back, the cause is still there and a licensed technician should check it.

Who can fix Daikin code b4 near me?

Aurora Star Tech Inc. repairs Daikin air handlers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Troubleshooting guides

Source: Daikin DX6VS/DZ6VS service instructions SiUS612209EA, p. 60. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.