Daikin Error Code F6: High pressure control in cooling (Mini-Split)

Updated · by Aurora Star Tech Inc.

Daikin error code F6 on a mini-split means: High pressure control in cooling. It is also called Daikin diagnostic code F6.

Medium severityMini-SplitDaikin FTX-W

Homeowner? What Daikin code F6 means for you

Check, then call Your ductless mini-split is reporting: High pressure control in cooling. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Safe things you can check yourself

  • Check the remote: fresh batteries and the right mode (Cool, Heat or Auto).
  • Check the breaker and the outdoor disconnect; both should be ON.
  • Open the front cover of the indoor unit and rinse the washable filters if they are dusty; let them dry before putting them back.
  • Keep the outdoor unit clear of snow, ice and leaves.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Daikin error code F6 mean?

Outdoor coil temperature went above 60 C (140 F) in cooling and the unit cut frequency or stopped. It clears below 47 C (116.6 F).

Applies to: FTX30/36WVJU9 with RX30/36WMVJU9 or RK30/36WMVJU9

Common causes of Daikin code F6

  • Not enough clearance around outdoor unit
  • Dirty outdoor coil
  • Faulty outdoor fan motor

A technician checks these and 4 other possible causes on site before replacing any part.

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Daikin models that use code F6

FTX30WVJU9FTX36WVJU9RK30WMVJU9RK36WMVJU9RX30WMVJU9RX36WMVJU9

Other Daikin Mini-Split codes

CodeMeaning
E5Compressor overload (OL) tripped
E6Compressor lock
E7Outdoor DC fan lock
E8Input overcurrent
EAFour way valve abnormality
F3Discharge pipe temperature too high
F8Compressor temperature abnormality shutdown
H0Compressor current sensor abnormality
H6Compressor position sensor abnormality (start failure)
H8Current transformer (CT) abnormality
H9Outdoor air thermistor fault
J3Discharge pipe thermistor fault

All Daikin Mini-Split error codes →

Daikin code F6: homeowner questions

What does Daikin code F6 mean?

High pressure control in cooling. Outdoor coil temperature went above 60 C (140 F) in cooling and the unit cut frequency or stopped. It clears below 47 C (116.6 F).

Is it safe to keep using my ductless mini-split with code F6?

It depends on the cause. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Can I reset Daikin code F6 myself?

You can try one reset (power off for 30 seconds, then on). If Daikin code F6 comes back, the cause is still there and a licensed technician should check it.

Who can fix Daikin code F6 near me?

Aurora Star Tech Inc. repairs Daikin ductless mini-splits in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: Daikin FTX-W service manual SiUS042228E, Troubleshooting 4.18, p.94. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.