Viessmann Versatronik 585 VI/BACIP Error Codes

Updated · by Aurora Star Tech Inc.

Viessmann Versatronik 585 VI/BACIP error codes and diagnostic codes (also listed as P/N 704098 (120VAC gateway)). The Versatronik 585 VI/BACIP is a Viessmann boiler in the Versatronik 585 series.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Viessmann Versatronik 585 VI/BACIP error codes list

CodeMeaningSeverity
00System without faultLow
0FMaintenance check-up dueLow
4CInterruption, supply temperature sensor heating circuit 3Medium
4dInterruption, return temperature sensor heating circuit 3Medium
9ASolar collector temperature sensor open circuitMedium
9BSolar collector return temperature sensor open circuitMedium
9CSolar DHW tank temperature sensor open circuitMedium
9FSolar general faultMedium
10Short circuit, outdoor temperature sensorMedium
18Interruption, outdoor temperature sensorMedium
20Short circuit, supply temperature sensor HC1/systemMedium
28Interruption, supply temperature sensor HC1/systemMedium
30Short circuit, boiler water temperature sensorMedium
38Interruption, boiler water temperature sensorMedium
40Short circuit, supply temperature sensor heating circuit 2Medium
41Short circuit, return temperature sensor heating circuit 2Medium
44Short circuit, supply temperature sensor heating circuit 3Medium
45Short circuit, return temperature sensor heating circuit 3Medium
48Interruption, supply temperature sensor heating circuit 2Medium
49Interruption, return temperature sensor heating circuit 2Medium
50Short circuit, DHW tank temperature sensorMedium
51Short circuit, DHW tank temperature sensor 2Medium
58Interruption, DHW tank temperature sensorMedium
59Interruption, DHW tank temperature sensor 2Medium
60Short circuit, return temperature sensor 17Medium
68Interruption, return temperature sensor 17Medium
70Short circuit, supply/return temperature sensor 17BMedium
78Interruption, supply/return temperature sensor 17BMedium
92Solar collector temperature short circuitMedium
93Solar collector return temperature short circuitMedium
94Solar collector DHW tank temperature sensor short circuitMedium
A7Wireless clock module faultLow
AEInternal fault mixing valveHigh
AFInternal fault mixing valveHigh
b0Short circuit, flue gas temperature sensorMedium
b1Communication fault, programming unit (internal)Low
b4Internal faultHigh
b5Internal faultHigh
b6Internal fault, invalid hardware recognitionHigh
b7Internal fault, boiler protection coding cardHigh
b8Interruption, flue gas temperature sensorMedium
bAFault, mixing valve module (KM-BUS)Medium
bCFault, Vitotrol heating circuit 1 (KM-BUS)Low
bdFault, Vitotrol heating circuit 2 (KM-BUS)Low
bEFault, Vitotrol heating circuit 3 (KM-BUS)Low
C1External fault indication, boilerMedium
C2Communication fault solar control unit (KM-BUS)Low
C5Fault, speed controlled pump heating circuit 1 (KM-BUS)Medium
C6Fault, speed controlled pump heating circuit 2 (KM-BUS)Medium
C7Fault, speed controlled pump heating circuit 3 (KM-BUS)Medium
C8Fault, water level controlMedium
C9Fault, maximum pressureCritical
CAFault, minimum pressure/maximum pressure 2High
CbFault, maximum pressure 2High
CCReserved, external peripheryLow
CdCommunication fault, Vitocom 300 (KM-BUS)Low
CECommunication fault, fault indicator module (KM-BUS)Low
CFCommunication fault: wrong LON moduleLow
d1Burner fault, boilerHigh
d4Fixed high limit fault, boilerCritical
d5Cascade: boiler is not respondingMedium
d6External fault 1, plug-in adaptorMedium
d7External fault 2, plug-in adaptorMedium
d8External fault 3, plug-in adaptorMedium
dAShort circuit, room temperature sensor heating circuit 1Medium
dbShort circuit, room temperature sensor heating circuit 2Medium
dCShort circuit, room temperature sensor heating circuit 3Medium
ddInterruption, room temperature sensor heating circuit 1Medium
dEInterruption, room temperature sensor heating circuit 2Medium
dFInterruption, room temperature sensor heating circuit 3Medium
E0Fault, external device connected to LONLow
E4Fault, power supply voltageMedium
E5Internal fault, combustion control unitHigh
E6Flue gas/air supply system blockedHigh
F0Communication fault, combustion control unitHigh
F1Flue gas temperature limit has trippedHigh
F2Temperature limit has trippedCritical
F3Flame signal present at burner startHigh
F4Flame signal not presentHigh
F5Air pressure switch not open for burner startHigh
F6Gas pressure switch not open for burner startHigh
F7Air pressure sensor short circuit or offset out of toleranceMedium
F8Fuel valve closure delayedHigh
F9Blower speed too low at burner startHigh
FABlower speed too high at burner startHigh
FCControl of modulation valve defectiveHigh
FDFault, combustion control unitHigh
FECoding plug defective or wrong EMV errorMedium
FFInternal faultHigh

Troubleshooting the Versatronik 585 VI/BACIP

All Viessmann Boiler error codes →

Homeowner help: Boiler Not Heating: What to Check

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.