Navien Error Code PD: High pressure too high in heating (Heat Pump)
Navien error code PD on a heat pump means: High pressure too high in heating. It is also called Navien diagnostic code PD.
Homeowner? What Navien code PD means for you
Call a technician Your heat pump is reporting: High pressure too high in heating. The heat pump has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.
Safe things you can check yourself
- Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
- Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
- Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
- In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
- Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.
Call (647) 657-2977Book a service call
Licensed technicians serving Vaughan, Toronto and the GTA.
What does Navien error code PD mean?
The pressure sensor read above 3.6 MPa (about 522 psi). This one is checked in heating mode.
Applies to: NAZ17V36 (24K/36K), NAZ17V60 (48K/60K)
Common causes of Navien code PD
- Poor indoor airflow in heating (filter, blower)
- Overcharge or air in the system
- Restriction
A technician checks these and 2 other possible causes on site before replacing any part.
Navien models that use code PD
Other Navien Heat Pump codes
All Navien Heat Pump error codes →
Navien code PD: homeowner questions
What does Navien code PD mean?
High pressure too high in heating. The pressure sensor read above 3.6 MPa (about 522 psi). This one is checked in heating mode.
Is it safe to keep using my heat pump with code PD?
It depends on the cause. The heat pump has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.
Can I reset Navien code PD myself?
You can try one reset (power off for 30 seconds, then on). If Navien code PD comes back, the cause is still there and a licensed technician should check it.
Who can fix Navien code PD near me?
Aurora Star Tech Inc. repairs Navien heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.
Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air
Troubleshooting guides
- 2 flashes: HPS open ≥6 s; 3: discharge >263°F; 4: discharge <90°F after 1 h; 5: defrost failure; 6: discharge sensor short; 7: outdoor sensor open/short; 9: bonnet sensor fail All brands · Heat Pump
- Excess ice on outdoor coil All brands · Heat Pump
- Extremely high head pressure in heating (dual fuel) All brands · Heat Pump
- Insufficient heat in cold weather All brands · Heat Pump
- Liquid slugging / compressor damage in heating All brands · Heat Pump
- No mode change / wrong mode All brands · Heat Pump
- Odour at registers (dirty sock) All brands · Heat Pump
- Poor heating but OK cooling (or vice-versa) All brands · Heat Pump
- Service problem analysis (Amana chart excerpt) All brands · Heat Pump
- Subcooling too high All brands · Heat Pump
- Subcooling too low vs mfr target All brands · Heat Pump
- TXV bulb/diaphragm failure All brands · Heat Pump
- Water-source: coil freezing All brands · Heat Pump
- Won't change mode / both coils same temperature All brands · Heat Pump
- Wrong superheat after line-set change; poor capacity All brands · Heat Pump
- Air space and ventilation requirements for the heat pump Navien · Heat Pump
- Duct installation rules Navien · Heat Pump
- Front panel shows Operation Prevention in Progress Navien · Heat Pump
- Heat source fallback when one heater or the heat pump fails Navien · Heat Pump
- IoT module dead (LED off) Navien · Heat Pump
- IoT module LED red or blinking red Navien · Heat Pump
- IoT module not working or will not pair with Multikit Navien · Heat Pump
- IoT module will not connect to Wi-Fi Navien · Heat Pump
- IoT module: Bluetooth LED blinking red (NaviLink) Navien · Heat Pump
- IoT module: both LEDs blinking red (Multikit) Navien · Heat Pump
- IoT module: both LEDs solid red Navien · Heat Pump
- Low hot water in winter or poor heat pump airflow Navien · Heat Pump
- Multikit app shows no data or graph stopped Navien · Heat Pump
Source: Navien NAZ Series Heat Pump Service Manual (V1.00), 4.2.10, p.37-38. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.