Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Navien Error Code HC: Lockout: discharge probe off the pipe (FE repeated) (Heat Pump)

Updated · by Aurora Star Tech Inc.

Navien error code HC on a heat pump means: Lockout: discharge probe off the pipe (FE repeated). It is also called Navien diagnostic code HC.

High severityHeat PumpNavien NAZ

Homeowner? What Navien code HC means for you

Call a technician Your heat pump is reporting: Lockout: discharge probe off the pipe (FE repeated). The heat pump has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Navien error code HC mean?

FE happened 3 times within 180 minutes for the T5 discharge probe and the unit has stopped.

Applies to: NAZ17V36 (24K/36K), NAZ17V60 (48K/60K)

Common causes of Navien code HC

  • T5 probe off the discharge line or wrong spot
  • Damaged sensor
  • Outdoor PCB fault
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Navien models that use code HC

NAZ17V36NAZ17V60

Other Navien Heat Pump codes

CodeMeaning
H3Lockout: high pressure in heating (PD repeated)
H4Lockout: drive module overheating (P8 repeated)
H5Lockout: low pressure (P2 repeated)
H6Lockout: high discharge temperature (P4 repeated)
H7Lockout: low discharge superheat (PC repeated)
H8Lockout: T3 probe off the pipe (FE repeated)
HERepeated condensate-risk faults (F8)
IoT LED bootIoT module boot mode
IoT LED pairingIoT module pairing / operation
IoT Wi-Fi LED colorIoT Wi-Fi signal color
L0DC bus voltage too low
L1DC bus voltage too high

All Navien Heat Pump error codes →

Navien code HC: homeowner questions

What does Navien code HC mean?

Lockout: discharge probe off the pipe (FE repeated). FE happened 3 times within 180 minutes for the T5 discharge probe and the unit has stopped.

Is it safe to keep using my heat pump with code HC?

It depends on the cause. The heat pump has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset Navien code HC myself?

You can try one reset (power off for 30 seconds, then on). If Navien code HC comes back, the cause is still there and a licensed technician should check it.

Who can fix Navien code HC near me?

Aurora Star Tech Inc. repairs Navien heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: Navien NAZ Series Heat Pump Service Manual (V1.00), 4.2.7, p.33. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service