Lennox furnace: Two-stage furnace ignition retries and watchguard

Updated · by Aurora Star Tech Inc.

A Lennox two-stage, variable-speed furnace (the EL296UHV, SL280UHV, SL280UHNV and SL297UHNV models) does not give up the first time the flame fails to catch. It has a built-in retry routine and a "watchguard" feature that keep trying on their own.

Homeowner with a furnace problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

How the Lennox furnace works: Two-stage furnace ignition retries and watchguard

What this is. A Lennox two-stage, variable-speed furnace (the EL296UHV, SL280UHV, SL280UHNV and SL297UHNV models) does not give up the first time the flame fails to catch. It has a built-in retry routine and a "watchguard" feature that keep trying on their own.

What happens, in order. Once the igniter has warmed up, the gas valve opens for a short four-second trial. If the furnace does not prove a flame in that time, it closes the valve, clears the chamber and warms up again for about 35 seconds before the next try. It makes five trials in total. If all five fail, the control moves into its flame-failure watchguard mode and waits. After 60 minutes it restarts the ignition sequence from the beginning.

The watchguard. If a call for heat has gone unanswered for a full hour, the watchguard also briefly breaks and remakes the thermostat call, which can clear an ignition lockout by itself. Lockouts caused by too many retries or recycles also clear once a later heat call finishes successfully.

What is normal. A pause and a few clicks before the burners light. Display codes in the E270 to E275 range and E290 belong to this routine.

Safe checks. Confirm the thermostat is set to Heat and above room temperature, the furnace switch and breaker are on, and the filter is clean. You may switch the furnace power off for ten seconds and back on once.

When to call a technician. If the furnace keeps cycling through retries, shows the same code again after one reset, or never produces heat, call Aurora Star Tech. If you ever smell gas, leave the house and call from outside.

Key times at a glance

WhatHow long or how much
Trials for ignition5 total
Inter-purge and warm-up between trials35 s
Watchguard reset60 min

Applies to: Two-stage variable-speed Lennox furnaces

Error codes linked to this step

Lennox code E270Lennox code E271Lennox code E272Lennox code E273Lennox code E274Lennox code E275Lennox code E290

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Questions about the Lennox furnace

What is the Two-stage furnace ignition retries and watchguard on a Lennox furnace?

A Lennox two-stage, variable-speed furnace (the EL296UHV, SL280UHV, SL280UHNV and SL297UHNV models) does not give up the first time the flame fails to catch. It has a built-in retry routine and a "watchguard" feature that keep trying on their own.

Is it normal for my Lennox furnace to do this?

A pause and a few clicks before the burners light. Display codes in the E270 to E275 range and E290 belong to this routine.

Who can service my Lennox furnace near me?

Aurora Star Tech Inc. repairs and services Lennox furnaces in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Furnace Repair

647-657-2977