Reset & cancel: Boiler tips (part 5 of 8)

Updated · by Aurora Star Tech Inc.

Short, practical technician tips on reset & cancel for boiler. Check each one against the manual for your exact model before acting.

Reset all codings to factory settings (input module)

Viessmann · 0-10 V input module 7134 561

Resets the codings on the 0-10 V input module. The button symbols in the source are not legible, so button names are described by position only.

  1. Press the two buttons together for about two seconds until the first two arrows appear in the display.
  2. Press the confirm button D.

Reset all operating parameters to factory settings

Viessmann · Vitocrossal 300 CA3B Dual Fuel Series 2.5 to 6.0

Restores every operating parameter to factory values through the service menu.

  1. Hold S for more than 2 seconds until the indicator flashes.
  2. Press Y until '6' shows under Service.
  3. Press S. '6' shows under Status.
  4. Press Y until '0' shows under Service.
  5. Press S. '1' shows under Status and 'dEL' under Service.
  6. Press S to confirm. '1' under Service means success, '0' means it failed.
  7. Press S to return to the operating display.

Reset all values to factory default

Viessmann · Vitotrol 300 remote control

The factory default button resets every adjustable value on the remote control, not just one setting. Write down any custom settings first.

  1. Press the factory default button (icon not legible in text) only if all values should be reset.
  2. Re-enter date, time, room temperatures and heating cycles after the reset.

Reset all values to factory settings (Vitotronic 100)

Viessmann · Vitotronic 100 GC1B

Resets all changed values at once. Factory settings include heating program (blank setting on display) and temperature unit °C.

  1. Press the settings key until its symbol flashes.
  2. Press the selector key until the reset symbol flashes.
  3. Press OK to confirm; the reset symbol flashes.
  4. Press OK again to confirm; the factory settings are restored.

Reset burner after a start-up fault caused by air in the gas line

Viessmann · Vitodens 222-F B2TB 19, 35, 68, 125

On first start-up, air in the gas supply pipe (especially with LPG) can cause a fault. The direct spark ignition retries after a reset.

  1. Wait about 5 seconds after the fault.
  2. Press the R reset button to reset the burner.
  3. The ignition procedure repeats.

Reset burner control unit after a fault

Viessmann · Vitocrossal 300 CA3B Dual Fuel 2.5 to 6.0

Correct the fault first, working through the measures in the order listed. Then reset the unit.

  1. Correct the fault using the measures for the displayed code (pages 28 to 31), in the order given.
  2. Press reset button R for longer than 0.5 seconds.
  3. The operating display returns and the burner control unit is reset.

Reset burner hours or burner starts to zero

Viessmann · Single-boiler and multi-boiler systems

Done from the scanning mode. The burner hours shown are approximate values only.

  1. Scan to the burner hours (1st or 2nd stage) or burner starts.
  2. Press the D button while that value is shown to reset it to 0.

Reset burner hours, fuel consumption and solar data

Viessmann · Vitocrossal 300 CU3A

Clears the stored data counters. Options are burner hours, fuel consumption, solar energy yield, solar circuit pump hours and output 22 hours, or all of them together.

  1. Open the extended menu.
  2. Select 'Information'.
  3. Select 'Reset data'.
  4. Choose the counter to reset.

Reset burner hours, fuel consumption or solar data

Viessmann · Vitocrossal 300 CA3B with Vitotronic 300 GW6C

You can reset burner hours run, fuel consumption, and in solar systems the solar energy yield, solar circuit pump hours and output hours. You can also reset all data at once. Select the item or All details, then confirm.

  1. From the home screen, open Menu, then Information.
  2. Open Reset data.
  3. Select the required data point or All details.
  4. Tap OK to confirm.
  5. Tap Confirm.

Reset burner operating time and burner starts

Viessmann · Cascade and multi-stage heat generators

Burner run time and start counts are shown per stage and can be reset per boiler.

  1. Select Burn operat time with the F button to show the current values.
  2. Use the F button to select the boiler and level.
  3. Select Reset with the F button.
  4. Press Cancel to leave the level.

Reset burner run hours and burner starts

Viessmann · Vitotronic 100 GC1 boiler control

Burner run hours and burner starts can be cleared from the scan display after service work.

  1. Open the operating condition scan (page 106).
  2. Select the run hours or burner starts display.
  3. Press D to reset the value to 0.

Reset button location

Viessmann · Vitodens 200-W and Vitocrossal 300 CU3A

The red fault indicator, green ON indicator, reset button and ON/OFF switch are on the boiler controls. On Vitodens 200-W the reset button is under the open side panels. On Vitocrossal 300 CU3A it is under the open panel covers.

  1. Open the side panels (Vitodens 200-W) or panel covers (Vitocrossal 300 CU3A).
  2. Find the reset button next to the fault indicator.
  3. Only reset after the fault cause has been corrected.

Reset central heating phases to factory settings

Viessmann · Central heating time program

If different phases were set per weekday, selecting '1-7' again resets all phases to their factory settings.

  1. While '1-7' is showing, press the confirm button to reset all time phases to factory settings.

Reset codes to factory default

Viessmann · Vitotronic 200-H

Restores the factory default settings.

  1. Press the w and rw keys together for about 2 seconds.
  2. Press D.
  3. Confirm with OK.

Reset codings to factory default

Viessmann · Vitotronic 200-H programming unit

Restores the factory coding values.

  1. Press the two buttons shown on the programming unit simultaneously for about 2 seconds, until the first two arrows appear.
  2. Press the D button.

Reset codings to factory setting

Viessmann · Vitotronic 300-K MW1S input module and control unit codings

Use this to return the coding addresses to their factory values.

  1. Press the w and rw buttons together for about two seconds, until the first two arrows appear in the display.
  2. Press the D button to confirm.

Reset data (solar and all data)

Viessmann · Solar thermal systems and general data reset

Resets solar energy yield, solar pump hours run and output 22 hours run, or all data at once. Only the solar items apply when a solar thermal system is present.

  1. From the home screen, open Information.
  2. Tap Reset data.
  3. Select the required data point or All data.
  4. Confirm.

Reset DHW time phases to factory settings

Viessmann · Vitotronic 200-H DHW time program

If different times were set for individual days, you can return all phases to the factory settings.

  1. With the display showing '1-7', press the reset button.
  2. All DHW time phases return to factory settings.

Reset faults with the tr rotary selector

Viessmann · Vitodens 100-W WB1B

Turning the tr selector to the reset position clears a fault. If no fault is present, the boiler goes into relay test mode instead. Turn the boiler off and back on to exit.

  1. Turn the tr rotary selector to "U Reset".
  2. Pause until "SERV" appears on the screen.
  3. Within 2 seconds, turn tr back into the control range.
  4. To leave relay test mode, turn the boiler off and back on.

Reset heating time cycles to factory settings

Viessmann · Vitotronic 300 Model GW2

If days have been set individually, selecting all days again resets every time cycle to the factory default.

  1. With '1-7' showing in the heating time program display, press the reset button shown in the manual.
  2. Confirm the reset as prompted.

Reset Input Module codings to factory setting

Viessmann · Input Module 0 to 10 V, Part No. 7134 561

Restores the 0 to 10 V Input Module codings to factory values.

  1. Press the w and rw keys together for about two seconds, until the first two arrows appear in the display.
  2. Press the D key to confirm.

Reset manual reset temperature limit switch

Viessmann · Vitocrossal 300 CA3B Dual Fuel Series 2.5 to 6.0

The supply water and flue gas temperature limit switches lock out mechanically when the probe temperature exceeds the limit. They are factory preset and must not be adjusted. The switch can only be reset after the temperature has dropped about 14°F (8°C) below the limit.

  1. Unscrew the reset cap and set it aside.
  2. Reset the switch.
  3. Reinstall the reset cap.
  4. If the switch cannot be reset, replace the switch.

Reset max flue gas temperature

Viessmann · Vitotronic 300 GW2

Resets the stored maximum flue gas temperature to the current value after maintenance.

  1. Press the 9 and rw buttons together for about 4 seconds.
  2. Press D to reset max flue gas temperature to the current value.
  3. Press the exit button.

Reset maximum flue gas temperature

Viessmann · Vitotronic 100 GC1 boiler control

The stored maximum flue gas temperature can be set back to the actual value.

  1. Press 9 and rw together for about four seconds to enter the maximum flue gas temperature display.
  2. Press D to reset the maximum flue gas temperature to the actual value.

Reset operating data (hours run etc.)

Viessmann · Vitocrossal 300 CA3B Dual Fuel

Saved operating data such as hours run can be set back to 0. The dampened outdoor temperature value resets to the actual outdoor value.

  1. From the home screen, tap Service and enter the viservice password.
  2. Tap Diagnosis, then Reset data.
  3. Select the required value, or All data.
  4. Note: the service menu exits automatically after 30 min.

Reset operating data (Vitotronic 200)

Viessmann · Vitotronic 200

Operating data reset on the Vitotronic 200 is covered in the boiler operating instructions.

  1. Refer to the Vitodens operating instructions for the reset procedure.

Reset operating data counters

Viessmann · Vitocrossal 300 CA3B Series 2.5 to 6.0

Saved operating data such as hours run can be reset to 0. The dampened outdoor temperature is reset to the actual value.

  1. From the home screen tap Service and enter the viservice password.
  2. Select Diagnosis, then Reset data.
  3. Select the required value or All data.

Reset operating parameters to factory settings

Viessmann · Vitocrossal 300 CA3B Dual Fuel 2.5 to 6.0

All operating parameters can be returned to their factory settings through menu item 6.

  1. Hold button S for more than 2 seconds until the menu indicator blinks.
  2. Press Y until 6 shows under Service.
  3. Press S. 6 shows under Status.
  4. Press Y until 0 shows under Service.
  5. Press S. 1 shows under Status and dEL shows under Service.
  6. Press S to confirm. 1 under Service means success, 0 means it failed.
  7. Press S to return to the operating display.

Reset parameters to factory values

Viessmann · Versatronik 200 service level

User, expert and time program values can each be restored to factory settings separately.

  1. Select the Reset function with the F button.
  2. Set it to On with the shaft encoder.
  3. Press OK to load the standard values for that level.
  4. Press Cancel to exit, or use the Home button.

Reset recorded data to 0 (Vitotronic 300-K)

Viessmann · Vitotronic 300-K MW1B with solar thermal system

Resets solar energy yield and solar pump hours, or all the above data together.

  1. Open the extended menu.
  2. Select Information, then Reset data.
  3. Select the data to reset: solar energy yield and hours run for solar circuit pump and output 22, or all data at once.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.