Other: Air Conditioner tips (part 2 of 2)
Short, practical technician tips on other for air conditioner. Check each one against the manual for your exact model before acting.
TXV upgrade on old fixed-orifice systems (Thinking Green)
Generic
Replacing a piston with a TXV on an older comfort system can noticeably improve efficiency under varying load.
Window unit tilt
Generic
Sleeve must slope ~1/4" down toward outside so condensate drains; unit dripping indoors = wrong slope or plugged drain hole.
Before any service on the unit
Navien · NAA17V36-24K/36K, NAA17V60-48K/60K
Isolate power and water before touching anything, let the unit cool, and confirm all error codes are diagnosed first.
- Turn off the electric power and the water shut-off valve.
- Wait for the unit to cool down before working on it, and watch for sharp edges.
- Diagnose all error codes before disassembling anything.
- Keep dust and foreign material out of the unit during reassembly.
- Check operation and performance after service.
Brazing and ventilation rules
Navien · NAA17V36-24K/36K, NAA17V60-48K/60K
Brazing and refrigerant work need open or well-ventilated space, and only brazed joints are acceptable on existing lines.
- Make sure the area is open or adequately ventilated before opening the system or brazing.
- Do not work in confined spaces.
- Only braze lines that are open to the atmosphere or properly exhausted.
- On existing refrigerant lines, confirm all joints are brazed, not soldered.
- Use a quenching cloth for brazing and keep a dry powder or CO2 extinguisher nearby.
Decommissioning and labeling
Navien · NAA17V36-24K/36K and NAA17V60-48K/60K
Before decommissioning, the technician must be familiar with the equipment and power must be available.
- Isolate the system electrically.
- Pump down the system if possible, or manifold the system to recover from all sections.
- Take an oil and refrigerant sample first if the refrigerant will be reused.
- Do not reuse recovered refrigerant until it has been cleaned and checked.
- Once emptied, label the equipment as dated, signed, and containing flammable refrigerant.
Electrical and high-pressure precautions before service
Navien · NAA outdoor unit
Electrical and refrigerant hazards apply before any work on the unit.
- Disconnect power before repairing or changing wiring.
- Label all wires before disconnecting them on the unit control.
- Disconnect all electric supplies before opening the access panel.
- Wait five minutes before servicing so electrical components discharge. Do not discharge capacitors by force.
- Recover the refrigerant before opening the system, because it contains high-pressure oil and refrigerant.
- Do not clean the unit with chemicals, chemically treated cloth, benzene, paint thinner, polishing powder or other solvents.
Fan blade and fan motor replacement
Navien · NAA17V36-24K/36K, NAA17V60-48K/60K
Remove the fan guard and fan blade first, then the motor. Refer to the wiring diagram for connector locations.
- Turn off the respective circuit breaker.
- Remove the 8 screws from the fan guard at the top of the unit and take the guard off.
- Disconnect the fan connectors from the PCB.
- Remove the 2 nuts that secure the fan blade and motor, then remove the fan blade.
- Remove the 4 screws and nuts that secure the motor to the fan cover net, then remove the motor.
Flammable refrigerant safety and leak detection
Navien · NAA17V36-24K/36K and NAA17V60-48K/60K
The system uses R454B, a mildly flammable A2L refrigerant. Never use a flame, halide torch, or any naked-flame detector to look for leaks. Use only electronic leak detectors made for A2L refrigerants, calibrated in clean air and set to the refrigerant's LFL. Leak detection fluids can be used, but avoid chlorine-based detergents, which can corrode copper.
- Remove all ignition sources before checking for a leak.
- Check for leaks with an A2L-rated electronic detector or a bubble or fluorescent leak fluid.
- If a leak needs brazing, recover all refrigerant, or isolate the leaking section with shut-off valves and recover from there, before any flame work.
- Use only components specified by Navien. Unapproved parts can ignite refrigerant from a leak.
Leak detection for A2L refrigerant
Navien · NAA17V36-24K/36K, NAA17V60-48K/60K
Open flames and halide torches must never be used to find leaks. Use only detectors rated for A2L refrigerant.
- Use an electronic leak detector designed for A2L refrigerants and confirm it is non-sparking and calibrated in a refrigerant-free area.
- Remove or extinguish all flames if a leak is suspected.
- If brazing is needed at a leak, recover the refrigerant or isolate that section with shut-off valves first.
- Use leak detection fluid only if it does not contain chlorine; use the bubble or fluorescent method.
Main control board connection points (NAA17V36)
Navien · NAA17V36
Overview of the main board connections shown in the appendix.
- Compressor connects at U, V and W.
- T3, T4 and TP sensors connect to the board.
- High pressure protection switch connects to the board.
- Pressure sensor connects to the board.
- Solenoid valve connects to the board.
- Crankcase heater connects to the board.
- DC fan motor connects to the board.
- Ground wire connects to the board.
- Power supply input L (L1) and N (L2) connect to the board.
- Display board connects to the main board.
PCB replacement
Navien · NAA17V36-24K/36K, NAA17V60-48K/60K
Record all parameter settings before swapping the board, because they must be re-entered afterwards.
- Turn off the respective circuit breaker.
- Remove the 7 screws from the PCB cover and take the cover off.
- Disconnect all connections from the PCB and remove it.
- Record all existing parameter settings before removal.
- Reconnect all wiring connectors to the new PCB.
- Fasten the 7 screws to reinstall the PCB cover.
- Restore power and set the previous parameters.
POE oil and filter drier when the system is opened
Navien · NAA17V36-24K/36K, NAA17V60-48K/60K
This R-454B system uses POE oil (VG74, VG75 or equivalent), which absorbs moisture quickly. Oil and filter drier handling is required whenever the sealed circuit is opened.
- Use only R-454B refrigerant and approved compressor oil.
- If the system has been exposed to air for more than 4 hours, change the compressor oil.
- Replace the filter drier every time the refrigerant system is opened.
Pre-season inspection and maintenance
Navien · NAA system
Do this at the start of each heating or cooling season.
- Turn off the unit and disconnect power.
- Check wires for damage and check for leaks.
- Replace indoor filters and outdoor coils as needed.
- Clean the indoor unit drain pans.
- Check airflow and confirm condensate drains are clear.
- Check the air filters.
- Check blower wheel alignment and balance, and clean it as needed.
Refrigerant recovery, evacuation and purging
Navien · NAA17V36-24K/36K and NAA17V60-48K/60K
Follow this order when opening the refrigerant circuit. Recovered refrigerant goes into labeled recovery cylinders and is never mixed.
- Recover the refrigerant following local and national rules.
- Evacuate the system.
- Purge tubing and braze joints with inert gas while brazing.
- Keep purging with inert gas when a flame is used to open the system.
- Purge with oxygen-free nitrogen, never compressed air or oxygen, and repeat until no refrigerant remains.
- Vent to atmospheric pressure before working on the system.
- Keep the vacuum pump outlet away from ignition sources and in a well-ventilated area.
- Do not overfill recovery cylinders above 80% of their capacity, and do not exceed cylinder pressure rating.
- Weigh recovered refrigerant on calibrated scales.
Repairing the refrigerant circuit (R-454B flammable refrigerant)
Navien · NAA outdoor unit
Follow this sequence before opening the refrigerant circuit for any repair. Use the required recovery equipment and handle the flammable refrigerant safely.
- Recover the refrigerant with a recovery pump certified for flammable refrigerants.
- Purge the circuit with nitrogen.
- Evacuate the circuit to 1,500 microns.
- Open the circuit only by cutting or brazing.
- Break the vacuum with a nitrogen purge, keeping the vacuum pump outlet away from any ignition source.
- Replace the filter drier every time the refrigerant circuit is opened.
Sensor and valve reference (T3, T4, T5, T7, Tfin, PT, PEV)
Navien · NAA17V36-24K/36K and NAA17V60-48K/60K
Reference list of what each sensor or valve controls. Use it to understand protection and control behavior.
- T3 (outdoor coil temperature): high temperature protection and outdoor fan control.
- T4 (ODU ambient temperature): limits maximum compressor frequency.
- T5 (compressor discharge temperature): high discharge temperature and low superheat protection.
- T7 (control board pipe temperature): control board condensation prevention.
- Tfin (IPM condenser temperature): high IPM temperature protection.
- PT (pressure transducer): senses evaporating pressure, controls compressor frequency, and provides low pressure protection.
- PEV (pressure equalizer valve): balances system pressure before compressor start-up.
Temperature sensor replacement (T3, T4, T5/TP, T7)
Navien · NAA17V36-24K/36K, NAA17V60-48K/60K
The sensors are removed from the thermistor holder after the covers come off. If the display reading is wrong but the resistance matches the temperature, the PCB is the likely fault.
- Turn off the respective circuit breaker.
- Remove the 10 screws from the top cover and the 18 screws from the bottom cover, then remove the upper covers and side panels.
- Pull the clip that holds the thermistor.
- Remove the thermistor from the thermistor holder.
- Disconnect the thermistor connector from the PCB and remove the thermistor.
- If resistance matches temperature but the display is wrong, replace the PCB.
Wait before working on electrical parts
Navien · NAA17V36-24K/36K, NAA17V60-48K/60K
Inverter capacitors hold charge after power is removed. Disconnect every remote power supply and lock it out before service.
- Disconnect all remote electrical power and lock or tag the supply so it cannot be energized by accident.
- Wait at least 5 minutes after power is off before touching anything electrical.
- Confirm the system has been isolated before opening any electrical cover or terminal.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.