Icon
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Lennox Error Code 39: No cooling when requested (AC)

Updated · by Aurora Star Tech Inc.

Lennox error code 39 on a air conditioner means: No cooling when requested. It is also called Lennox diagnostic code 39.

High severityAir ConditionerAlso Air HandlerAlso FurnaceAlso Heat Pump

Homeowner? What Lennox code 39 means for you

Call a technician Your air conditioner is reporting: No cooling when requested. The air conditioner has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • Keep about 2 feet around the outdoor unit clear of leaves, grass and debris.
  • If you see ice on the pipes or the indoor coil, turn the system off and run only the fan for a few hours, then call a technician.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Lennox error code 39 mean?

Cooling could not be turned on for more than 45 minutes; the system goes off-line for 60 minutes, then tries to restart. S30/S40 thermostat alert code 39.

Applies to: Lennox communicating air conditioners incl. variable-capacity inverter units in S30/S40 smart thermostat systems

Common causes of Lennox code 39

  • Outdoor unit fault or lockout
  • Wiring or communication problem
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Lennox models that use code 39

EL16KC1-018-230AEL16KC1-024-230AEL16KC1-030-230AEL16KC1-036-230AEL16KC1-041-230AEL16KC1-042-230AEL16KC1-047-230AEL16KC1-048-230AEL16KC1-060-230A

Other Lennox AC codes

CodeMeaning
32Device resetting
34Must program unit capacity for device
35Incorrect operation of device
36Heating when not requested
37Cooling when not requested
38Not heating when requested
41Device control board replaced
611High room temperature detected
700Thermostat temperature sensor problem
701Thermostat temperature above limit
703Thermostat humidity sensor problem
3000Replace filter 1

All Lennox Air Conditioner error codes →

Lennox code 39: homeowner questions

What does Lennox code 39 mean?

No cooling when requested. Cooling could not be turned on for more than 45 minutes; the system goes off-line for 60 minutes, then tries to restart. S30/S40 thermostat alert code 39.

Is it safe to keep using my air conditioner with code 39?

It depends on the cause. The air conditioner has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset Lennox code 39 myself?

You can try one reset (power off for 30 seconds, then on). If Lennox code 39 comes back, the cause is still there and a licensed technician should check it.

Who can fix Lennox code 39 near me?

Aurora Star Tech Inc. repairs Lennox air conditioners in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check

Troubleshooting guides

Source: Lennox Residential Communicating Systems Alert Code Guide (V2) 100017 (3/2023), Table 2 Alert Codes and Troubleshooting, p.12. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977