Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

KeepRite *CA660 Error Codes

Updated · by Aurora Star Tech Inc.

KeepRite *CA660 error codes and diagnostic codes. The *CA660 is a KeepRite air conditioner in the KeepRite *CA/*CH Two-Stage Communicating series.

Homeowner with a air conditioner problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

KeepRite *CA660 error codes list

CodeMeaningSeverity
16Lost communication with wall controlMedium
25Model plug missing or invalidHigh
31High pressure switch openHigh
45Outdoor control board failureHigh
46Brown-out (low voltage)Medium
47No 230 V at the unitHigh
53Outdoor air temperature sensor faultMedium
55Outdoor coil sensor faultMedium
56Air and coil sensors disagreeMedium
71Low stage thermal cutoutHigh
72Compressor thermal cutout (two-stage: high stage)High
73Contactor stuck closedHigh
74No 230 V at compressorHigh
81Low stage thermal lockoutHigh
82Thermal lockout (two-stage: high stage)High
83Low pressure lockoutHigh
84High pressure lockoutHigh
Amber 1 flashRunning - cooling / low stage (normal)Low
Amber 2 flashesHigh stage running (normal)Low
Amber 5 flashesBrown-out protection turned off (user setting)Low
Amber 6 flashesBrown-out protection active (user setting)Low
Amber LED on solidStandby - no call (communicating)Low
Brown-out defeat toggleTurn 230 V brown-out protection off or onLow

Troubleshooting the *CA660

All KeepRite Air Conditioner error codes →

Homeowner help: AC Running But Not Cooling: What to Check

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977