Updated · by Aurora Star Tech Inc.

HTP error code LOU on a boiler means: 24 volt supply low. It is also called HTP diagnostic code LOU.

Medium severityBoilerElite EL

Homeowner? What HTP code LOU means for you

Check, then call Your boiler is reporting: 24 volt supply low. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Look at the pressure gauge on the boiler. If it reads much lower than usual or near zero, or water is leaking, call a technician.
  • Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
  • Check that the boiler gas valve is open (handle in line with the pipe).
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does HTP error code LOU mean?

Control's 24 V supply is damaged or overloaded; pump on. Clears itself if the overload goes away.

Applies to: EL-80, EL-110, EL-150, EL-220, EL-299, EL-399 (N/LP)

Common causes of HTP code LOU

  • Line voltage out of range
  • Shorted external sensor wiring
  • Short in the low voltage harness

A technician checks these and 3 other possible causes on site before replacing any part.

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

HTP models that use code LOU

EL-80 LPEL-80 NEL-110 LPEL-110 NEL-150 LPEL-150 NEL-220 LPEL-220 NEL-299 LPEL-299 NEL-399 LPEL-399 N

Other HTP Boiler codes

CodeMeaning
F31Program error
FLLow water flow
FLUHigh flue pressure
FOUOutdoor sensor fault
GAS VALVE ON / RUNIgnition then run status
LOCKOUTLockout (display message)
MAINTENANCE REQUIREDService reminder
PPControl programmed
PROLow water pressure
SERVICE PUMP CH / DH / SHPump service mode
SERVICE RUNTest mode running
TTTemperature blocking - thermostat (TT) demand

All HTP Boiler error codes →

HTP code LOU: homeowner questions

What does HTP code LOU mean?

24 volt supply low. Control's 24 V supply is damaged or overloaded; pump on. Clears itself if the overload goes away.

Is it safe to keep using my boiler with code LOU?

It depends on the cause. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Can I reset HTP code LOU myself?

You can try one reset (power off for 30 seconds, then on). If HTP code LOU comes back, the cause is still there and a licensed technician should check it.

Who can fix HTP code LOU near me?

Aurora Star Tech Inc. repairs HTP boilers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Boiler Not Heating: What to Check

Troubleshooting guides

Source: Elite EL-80 N Installation Manual (LP-293), p. 68. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.