Gree Error Code U7: Reversing (4-way) valve fault (Heat Pump)

Updated · by Aurora Star Tech Inc.

Gree error code U7 on a heat pump means: Reversing (4-way) valve fault. It is also called Gree diagnostic code U7.

High severityHeat PumpGree Sapphire · Gree Livo GEN4 · Gree Vireo GEN3 · Gree Multi21+

Homeowner? What Gree code U7 means for you

Call a technician Your heat pump is reporting: Reversing (4-way) valve fault. The heat pump has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Gree error code U7 mean?

The 4-way valve is not switching correctly; in heating the unit stops.

Applies to: Gree Sapphire 9-24k (SAP..HP230V1A), Livo GEN4 30-36k (4LIV..HP230V1A), Vireo GEN3 9-24k (3VIR..HP115/230V1A), Multi21+ 18-24k multi-zone (MULTI..HP230V1CO)

Common causes of Gree code U7

  • Supply below 175 VAC
  • 4-way valve coil wire loose or broken
  • Valve coil or valve failed
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Gree models that use code U7

3VIR09HP115V1A3VIR09HP230V1A3VIR12HP115V1A3VIR12HP230V1A3VIR18HP230V1A3VIR24HP230V1A4LIV30HP230V1AH4LIV36HP230V1AHMULTI18HP230V1COMULTI24HP230V1COSAP09HP230V1AHSAP12HP230V1AHSAP18HP230V1AHSAP24HP230V1AH

Other Gree Heat Pump codes

CodeMeaning
U1Compressor phase current sensing fault
U2Outdoor capacity code / jumper wrong
U3DC bus voltage drop
U4Refrigerant shortage at startup
U5Whole-unit current sensing fault
U6Service valves not opened
U8Indoor zero-crossing signal fault
U9Outdoor zero-crossing fault
UERefrigerant charging invalid

All Gree Heat Pump error codes →

Gree code U7: homeowner questions

What does Gree code U7 mean?

Reversing (4-way) valve fault. The 4-way valve is not switching correctly; in heating the unit stops.

Is it safe to keep using my heat pump with code U7?

It depends on the cause. The heat pump has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset Gree code U7 myself?

You can try one reset (power off for 30 seconds, then on). If Gree code U7 comes back, the cause is still there and a licensed technician should check it.

Who can fix Gree code U7 near me?

Aurora Star Tech Inc. repairs Gree heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: Gree Sapphire 9-12k (SAP09-12HP230V1A) service.pdf - section 9.1 Error Code List / 9.2 Procedure of Troubleshooting; Gree Sapphire 18-24k (SAP18-24HP230V1A) service.pdf - section 9.1 Error Code List / 9.2 Procedure of Troubleshooting; Gree Livo GEN4 30-36k (4LIV30-36HP230V1A) service.pdf - section 9.1 Error Code List / 9.2 Procedure of Troubleshooting; Gree Vireo GEN3 9-24k (3VIR..HP115-230V1A) service GREE_VIREOGEN3_SERVICE_090921.pdf - section 9.1 Error Code List / 9.2 Procedure of Troubleshooting; Gree Multi21+ multi-zone 18-24k (MULTI18-24HP230V1CO) service.pdf - section 9.1 Malfunction status sheet / 9.2 Malfunction Checking and Elimination. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.