Gree Error Code U9: Outdoor zero-crossing fault (Heat Pump)

Updated · by Aurora Star Tech Inc.

Gree error code U9 on a heat pump means: Outdoor zero-crossing fault. It is also called Gree diagnostic code U9.

High severityHeat PumpGree Sapphire

Homeowner? What Gree code U9 means for you

Call a technician Your heat pump is reporting: Outdoor zero-crossing fault. The heat pump has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Gree error code U9 mean?

The outdoor board cannot detect the supply zero-crossing.

Applies to: Gree Sapphire 9-24k (SAP..HP230V1A)

Common causes of Gree code U9

  • Outdoor board fault
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Gree models that use code U9

SAP09HP230V1AHSAP12HP230V1AHSAP18HP230V1AHSAP24HP230V1AH

Other Gree Heat Pump codes

CodeMeaning
U3DC bus voltage drop
U4Refrigerant shortage at startup
U5Whole-unit current sensing fault
U6Service valves not opened
U7Reversing (4-way) valve fault
U8Indoor zero-crossing signal fault
UCMaster indoor unit set successfully
UERefrigerant charging invalid
WiFi iconWiFi function on
X-FAN iconX-FAN (coil dry-off) active

All Gree Heat Pump error codes →

Gree code U9: homeowner questions

What does Gree code U9 mean?

Outdoor zero-crossing fault. The outdoor board cannot detect the supply zero-crossing.

Is it safe to keep using my heat pump with code U9?

It depends on the cause. The heat pump has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset Gree code U9 myself?

You can try one reset (power off for 30 seconds, then on). If Gree code U9 comes back, the cause is still there and a licensed technician should check it.

Who can fix Gree code U9 near me?

Aurora Star Tech Inc. repairs Gree heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: Gree Sapphire 9-12k (SAP09-12HP230V1A) service.pdf - section 9.1 Error Code List / 9.2 Procedure of Troubleshooting; Gree Sapphire 18-24k (SAP18-24HP230V1A) service.pdf - section 9.1 Error Code List / 9.2 Procedure of Troubleshooting. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977