Gree Error Code Ld: Compressor phase loss (Heat Pump)
Gree error code Ld on a heat pump means: Compressor phase loss. It is also called Gree diagnostic code Ld.
Homeowner? What Gree code Ld means for you
Call a technician Your heat pump is reporting: Compressor phase loss. The heat pump has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.
Safe things you can check yourself
- Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
- Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
- Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
- In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
- Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.
Call (647) 657-2977Book a service call
Licensed technicians serving Vaughan, Toronto and the GTA.
What does Gree error code Ld mean?
The compressor drive found one phase open. It retries after 1 min; after 6 tries it needs a power reset.
Applies to: Gree Multi21+ 18-24k multi-zone (MULTI..HP230V1CO)
Common causes of Gree code Ld
- Compressor U/V/W wire loose or broken
- Compressor winding open
- Board fault
Gree models that use code Ld
MULTI18HP230V1COMULTI24HP230V1CO
Other Gree Heat Pump codes
All Gree Heat Pump error codes →
Gree code Ld: homeowner questions
What does Gree code Ld mean?
Compressor phase loss. The compressor drive found one phase open. It retries after 1 min; after 6 tries it needs a power reset.
Is it safe to keep using my heat pump with code Ld?
It depends on the cause. The heat pump has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.
Can I reset Gree code Ld myself?
You can try one reset (power off for 30 seconds, then on). If Gree code Ld comes back, the cause is still there and a licensed technician should check it.
Who can fix Gree code Ld near me?
Aurora Star Tech Inc. repairs Gree heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.
Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air
Troubleshooting guides
- 2 flashes: HPS open ≥6 s; 3: discharge >263°F; 4: discharge <90°F after 1 h; 5: defrost failure; 6: discharge sensor short; 7: outdoor sensor open/short; 9: bonnet sensor fail All brands · Heat Pump
- Auxiliary heat indicator light is on All brands · Heat Pump
- Cleaning the outdoor unit finish All brands · Heat Pump
- Excess ice on outdoor coil All brands · Heat Pump
- Extremely high head pressure in heating (dual fuel) All brands · Heat Pump
- Insufficient heat in cold weather All brands · Heat Pump
- Liquid slugging / compressor damage in heating All brands · Heat Pump
- No mode change / wrong mode All brands · Heat Pump
Source: Gree Multi21+ multi-zone 18-24k (MULTI18-24HP230V1CO) service.pdf - section 9.1 Malfunction status sheet / 9.2 Malfunction Checking and Elimination. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.