Goodman Error Code CoreSense solid red: Solid red TRIP – call present but compressor not running (Heat Pump)
Goodman error code CoreSense solid red on a heat pump means: Solid red TRIP - call present but compressor not running. It is also called Goodman diagnostic code CoreSense solid red.
Homeowner? What Goodman code CoreSense solid red means for you
Call a technician Your heat pump is reporting: Solid red TRIP - call present but compressor not running. The heat pump has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.
Safe things you can check yourself
- Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
- Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
- Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
- In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
- Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.
Call (647) 657-2977Book a service call
Licensed technicians serving Vaughan, Toronto and the GTA.
What does Goodman error code CoreSense solid red mean?
Red LED steady: the module sees a Y demand but the compressor is not running.
Applies to: Copeland CoreSense 3-wire module: Amana/Deluxe R-410A ASX, ASZ, DSX, DSZ units and Amana R-32 ALXS / ALZS units
Common causes of Goodman code CoreSense solid red
- Compressor protector open (check head pressure and compressor voltage)
- Outdoor disconnect open
- Compressor breaker or fuses open
A technician checks these and 3 other possible causes on site before replacing any part.
Goodman models that use code CoreSense solid red
Show all 122 models
ALZS4BA**10AAALZS4NA**10AAALZS5BA**10AAANZ130181ANZ130241ANZ130301ANZ130361ANZ130421ANZ130481ANZ130601ANZ140181ANZ140241ANZ140301ANZ140361ANZ140421ANZ140481ANZ140491ANZ140601ASZ130181ASZ130241ASZ130301ASZ130361ASZ130421ASZ130481ASZ130601ASZ140181ASZ140241ASZ140301ASZ140361ASZ140381ASZ140421ASZ140481ASZ140491ASZ140601ASZ160181ASZ160241ASZ160301ASZ160361ASZ160421ASZ160481ASZ160601ASZ180361ASZ180481ASZ180601ASZH5***10DSZ160241DSZ160361DSZ160481DSZ160601DSZ180361DSZ180481DSZ180601GLZS4BA**10AAGLZS4MA**10AAGLZS5BA**10AAGSZ110903GSZ110904GSZ111203GSZ111204GSZ130181GSZ130191GSZ130241GSZ130251GSZ130301GSZ130311GSZ130361GSZ130363GSZ130371GSZ130421GSZ130481GSZ130483GSZ130484GSZ130601GSZ140181GSZ140241GSZ140301GSZ140361GSZ140371GSZ140421GSZ140481GSZ140491GSZ140601GSZ160181GSZ160241GSZ160301GSZ160361GSZ160421GSZ160481GSZ160601GSZH5***10SSZ140181SSZ140191SSZ140241SSZ140251SSZ140301SSZ140311SSZ140361SSZ140371SSZ140381SSZ140421SSZ140481SSZ140601SSZ160241SSZ160361SSZ160421SSZ160481SSZ160601VSZ130181VSZ130241VSZ130301VSZ130361VSZ130421VSZ130481VSZ130601VSZ140181VSZ140241VSZ140301VSZ140361VSZ140421VSZ140481VSZ140491VSZ140601
Other Goodman Heat Pump codes
All Goodman Heat Pump error codes →
Goodman code CoreSense solid red: homeowner questions
What does Goodman code CoreSense solid red mean?
Solid red TRIP - call present but compressor not running. Red LED steady: the module sees a Y demand but the compressor is not running.
Is it safe to keep using my heat pump with code CoreSense solid red?
It depends on the cause. The heat pump has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.
Can I reset Goodman code CoreSense solid red myself?
You can try one reset (power off for 30 seconds, then on). If Goodman code CoreSense solid red comes back, the cause is still there and a licensed technician should check it.
Who can fix Goodman code CoreSense solid red near me?
Aurora Star Tech Inc. repairs Goodman heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.
Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air
Troubleshooting guides
- No heat - R-32 GLZS/ALZS heat pump Goodman · Heat Pump
- Outdoor coil iced / no defrost - R-32 GLZS/ALZS heat pump Goodman · Heat Pump
- Reversing valve not shifting - ComfortNet heat pumps Goodman · Heat Pump
Source: Goodman RS6200301 R-32 GLXS/ALXS/GLZS/ALZS service (07-2024), CoreSense Diagnostics Table p.21-22 and Quick Reference Table p.23; Goodman RS6200006r103 R-410A ASX/GSX/DSX/ASZ/GSZ/DSZ service (text export) (Goodman_R_410A_ASX_GSX_DSX_A_C_and_ASZ_GSZ_DSZ_HP_covers_GSX_GSZ_lines_GSXH5_GSZH5_service.txt section Diagnostics Table: Coresense Module / Table 1 Quick Reference). Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.