Goodman Error Code CoreSense 4: Locked rotor – yellow 4 (red 4 = lockout) (Heat Pump)
Goodman error code CoreSense 4 on a heat pump means: Locked rotor - yellow 4 (red 4 = lockout). It is also called Goodman diagnostic code CoreSense 4.
Homeowner? What Goodman code CoreSense 4 means for you
Stop and call Your heat pump is reporting: Locked rotor - yellow 4 (red 4 = lockout). This code is a safety shutdown. Turn the heat pump off and call a licensed technician. Do not keep resetting it. If you smell gas, leave the house and call your gas utility or 911 from outside.
Safe things you can check yourself
- Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
- Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
Call (647) 657-2977Book a service call
Licensed technicians serving Vaughan, Toronto and the GTA.
What does Goodman error code CoreSense 4 mean?
Compressor trips within 12 s of running and will not start within 35 s. Red 4 flashes = locked out after 10 locked-rotor events in a row.
Applies to: Copeland CoreSense 3-wire module: Amana/Deluxe R-410A ASX, ASZ, DSX, DSZ units and Amana R-32 ALXS / ALZS units
Common causes of Goodman code CoreSense 4
- Failed run capacitor
- Low line voltage or poor connections
- Liquid refrigerant in the compressor
A technician checks these and 1 other possible causes on site before replacing any part.
Goodman models that use code CoreSense 4
Show all 122 models
ALZS4BA**10AAALZS4NA**10AAALZS5BA**10AAANZ130181ANZ130241ANZ130301ANZ130361ANZ130421ANZ130481ANZ130601ANZ140181ANZ140241ANZ140301ANZ140361ANZ140421ANZ140481ANZ140491ANZ140601ASZ130181ASZ130241ASZ130301ASZ130361ASZ130421ASZ130481ASZ130601ASZ140181ASZ140241ASZ140301ASZ140361ASZ140381ASZ140421ASZ140481ASZ140491ASZ140601ASZ160181ASZ160241ASZ160301ASZ160361ASZ160421ASZ160481ASZ160601ASZ180361ASZ180481ASZ180601ASZH5***10DSZ160241DSZ160361DSZ160481DSZ160601DSZ180361DSZ180481DSZ180601GLZS4BA**10AAGLZS4MA**10AAGLZS5BA**10AAGSZ110903GSZ110904GSZ111203GSZ111204GSZ130181GSZ130191GSZ130241GSZ130251GSZ130301GSZ130311GSZ130361GSZ130363GSZ130371GSZ130421GSZ130481GSZ130483GSZ130484GSZ130601GSZ140181GSZ140241GSZ140301GSZ140361GSZ140371GSZ140421GSZ140481GSZ140491GSZ140601GSZ160181GSZ160241GSZ160301GSZ160361GSZ160421GSZ160481GSZ160601GSZH5***10SSZ140181SSZ140191SSZ140241SSZ140251SSZ140301SSZ140311SSZ140361SSZ140371SSZ140381SSZ140421SSZ140481SSZ140601SSZ160241SSZ160361SSZ160421SSZ160481SSZ160601VSZ130181VSZ130241VSZ130301VSZ130361VSZ130421VSZ130481VSZ130601VSZ140181VSZ140241VSZ140301VSZ140361VSZ140421VSZ140481VSZ140491VSZ140601
Other Goodman Heat Pump codes
All Goodman Heat Pump error codes →
Goodman code CoreSense 4: homeowner questions
What does Goodman code CoreSense 4 mean?
Locked rotor - yellow 4 (red 4 = lockout). Compressor trips within 12 s of running and will not start within 35 s. Red 4 flashes = locked out after 10 locked-rotor events in a row.
Is it safe to keep using my heat pump with code CoreSense 4?
No. Code CoreSense 4 is a safety shutdown, so keep the heat pump off until a licensed technician has checked it.
Can I reset Goodman code CoreSense 4 myself?
Do not keep resetting it. Repeated resets can hide a safety problem; a licensed technician needs to find the cause.
Who can fix Goodman code CoreSense 4 near me?
Aurora Star Tech Inc. repairs Goodman heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.
Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air
Troubleshooting guides
- 2 flashes: HPS open ≥6 s; 3: discharge >263°F; 4: discharge <90°F after 1 h; 5: defrost failure; 6: discharge sensor short; 7: outdoor sensor open/short; 9: bonnet sensor fail All brands · Heat Pump
- Auxiliary heat indicator light is on All brands · Heat Pump
- Cleaning the outdoor unit finish All brands · Heat Pump
- Excess ice on outdoor coil All brands · Heat Pump
- Extremely high head pressure in heating (dual fuel) All brands · Heat Pump
- Insufficient heat in cold weather All brands · Heat Pump
- Liquid slugging / compressor damage in heating All brands · Heat Pump
- No mode change / wrong mode All brands · Heat Pump
Source: Goodman RS6200301 R-32 GLXS/ALXS/GLZS/ALZS service (07-2024), CoreSense Diagnostics Table p.21-22 and Quick Reference Table p.23; Goodman RS6200006r103 R-410A ASX/GSX/DSX/ASZ/GSZ/DSZ service (text export) (Goodman_R_410A_ASX_GSX_DSX_A_C_and_ASZ_GSZ_DSZ_HP_covers_GSX_GSZ_lines_GSXH5_GSZH5_service.txt section Diagnostics Table: Coresense Module / Table 1 Quick Reference). Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.