Fujitsu Error Code 11: Serial communication error (indoor/outdoor) (Heat Pump)

Updated · by Aurora Star Tech Inc.

Fujitsu error code 11 on a heat pump means: Serial communication error (indoor/outdoor). It is also called Fujitsu diagnostic code 11.

High severityHeat PumpFujitsu ductless split/multi/VRF (general code list) · Fujitsu wall-mounted 7-15 (NA ASU/AOU type) · Fujitsu slim duct ARU 7-18 (LL type)

Homeowner? What Fujitsu code 11 means for you

Call a technician Your heat pump is reporting: Serial communication error (indoor/outdoor). The heat pump has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Fujitsu error code 11 mean?

Indoor and outdoor boards are not hearing each other on the connection cable. On the UK service data the indoor unit flags it when no signal arrives from outdoor for over 2 min after power-up or 15 s in operation; the outdoor flags it after 10 s without indoor signal. Indoor lamps: OPERATION (green) flashes 1x, TIMER (orange) flashes 1x, ECONOMY (green) flashes fast nonstop; wired remote shows 11.

Applies to: Fujitsu ductless heat pumps: Fujitsu ductless split/multi/VRF (general code list), Fujitsu wall-mounted 7-15 (NA ASU/AOU type), Fujitsu slim duct ARU 7-18 (LL type)

Common causes of Fujitsu code 11

  • Loose, wrong or broken wire on terminals 1-2-3
  • Supply voltage out of range
  • Electrical noise / poor ground

A technician checks these and 2 other possible causes on site before replacing any part.

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Other Fujitsu Heat Pump codes

CodeMeaning
3AIndoor communication circuit (wired remote) error
5UIndoor unit error (general)
6ADisplay PCB micro communication error
9AExpansion valve coil error
9UOutdoor unit error (general)
12Wired remote controller communication error
14Network communication error
15Check run unfinished / airflow auto-adjust error
16Peripheral unit / transmission PCB connection error
21Address / refrigerant circuit setting error
22Indoor unit capacity error
23Combination error

All Fujitsu Heat Pump error codes →

Fujitsu code 11: homeowner questions

What does Fujitsu code 11 mean?

Serial communication error (indoor/outdoor). Indoor and outdoor boards are not hearing each other on the connection cable. On the UK service data the indoor unit flags it when no signal arrives from outdoor for over 2 min after power-up or 15 s in operation; the outdoor flags it…

Is it safe to keep using my heat pump with code 11?

It depends on the cause. The heat pump has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset Fujitsu code 11 myself?

You can try one reset (power off for 30 seconds, then on). If Fujitsu code 11 comes back, the cause is still there and a licensed technician should check it.

Who can fix Fujitsu code 11 near me?

Aurora Star Tech Inc. repairs Fujitsu heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: Fujitsu All Fujitsu split - multi - VRF (generic code list) codes.pdf - section error code table (indoor LED flashes); Fujitsu Wall-mounted 7-9-12-15 (North American trilingual, UTY-RNNUM remotes; e.g. ASU9-12-15 RLF1-RLS familie.pdf - section 14 Error codes; Fujitsu Wall-mounted KMCG (ASEH-AOEH 07-14) - Fujitsu UK; same error-code scheme as NA ASU-AOU units service S.pdf - section 3 Troubleshooting, 2 Troubleshooting with error code; Fujitsu Slim duct AR07-09-12-14-18 (ARU-ARYG LL-type equivalent) installation P-N 9381858064.pdf - section 14 Error codes. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977