Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

FlowMax Error Code OFF: Switched off, frost protection still active (Combi Boiler)

Updated · by Aurora Star Tech Inc.

FlowMax error code OFF on a combi boiler means: Switched off, frost protection still active. It is also called FlowMax diagnostic code OFF.

Low severityCombi BoilerFlowMax condensing combi (FLOWMAX-120)

Homeowner? What FlowMax code OFF means for you

Usually minor Your combi boiler is reporting: Switched off, frost protection still active. This code is usually informational or minor. The safe checks below often clear it; call us if it keeps showing up.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Look at the pressure gauge on the boiler. If it reads much lower than usual or near zero, or water is leaking, call a technician.
  • Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
  • Check that the boiler gas valve is open (handle in line with the pipe).
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.
  • If only hot water is missing, check that the hot water tap is open far enough to start the heater.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does FlowMax error code OFF mean?

The word OFF is shown when the ON/OFF switch on the control panel is in the off position. This is normal. Frost protection for the heating and hot water circuits stays enabled, and if the unit was running it carries out its fan post-purge, pump overrun and 3-way valve exercise functions. A connected remote control stays lit.

Applies to: FLOWMAX-120 condensing combi water heater

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Other FlowMax Combi Boiler codes

CodeMeaning
E14Air pressure switch tripped
E16Fan (blower) fault
E22Parameter programming request
E35Flame detection fault (false flame)
E42Fan speed control board fault
H2OLow water pressure in heating circuit
Outdoor tempOutdoor temperature readout
PL 0Parameter menu entered
Summer/Winter mode symbolsSummer and winter mode selected (heating and hot water)
Summer mode symbolSummer mode selected (hot water only)
Winter mode symbolWinter mode selected (heating only)

All FlowMax Combi Boiler error codes →

FlowMax code OFF: homeowner questions

What does FlowMax code OFF mean?

Switched off, frost protection still active. The word OFF is shown when the ON/OFF switch on the control panel is in the off position. This is normal. Frost protection for the heating and hot water circuits stays enabled, and if the unit was running it carries out its fan…

Is it safe to keep using my combi boiler with code OFF?

Usually yes. Code OFF is normally minor, but if it keeps coming back have it checked.

Can I reset FlowMax code OFF myself?

You can try one reset (power off for 30 seconds, then on). If FlowMax code OFF comes back, the cause is still there and a licensed technician should check it.

Who can fix FlowMax code OFF near me?

Aurora Star Tech Inc. repairs FlowMax combi boilers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Tankless Water Heater No Hot Water: What to Check · Boiler Not Heating: What to Check

Troubleshooting guides

Source: FLOWMAX-120 Instruction Manual, 2.6/2.7 Operation / Functions display and Control panel, p.15. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.