FlowMax Combi Boiler: Enter the parameter menu (PL 0)
Enter the parameter menu (PL 0) on a FlowMax combi boiler: Power-up button combination that opens parameter selection; the display shows PL and 0 when it is ready.
Applies to: FLOWMAX-120 condensing combi
How to fix enter the parameter menu (pl 0): step by step
- Switch the ON/OFF switch to OFF.
- Switch it back ON while holding the + and - buttons.
- Release both buttons when PL and 0 appear.
- Hold S and press + to choose a parameter number, release S, then press S again to see its value.
- Change the value with + or -, press S to confirm, then switch the unit off and on to apply it.
If the unit shows an error code, look it up: FlowMax Combi Boiler codes
More access & passwords tips for combi boiler
Source: FLOWMAX-120 Instruction Manual, 5.2 Setting the parameters, p.40. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.