Gree Error Code EU: Compressor slowed – module running hot (Heat Pump)

Updated · by Aurora Star Tech Inc.

Gree error code EU on a heat pump means: Compressor slowed - module running hot. It is also called Gree diagnostic code EU.

Low severityHeat PumpGree Sapphire · Gree Livo GEN4 · Gree Vireo GEN3

Homeowner? What Gree code EU means for you

Usually minor Your heat pump is reporting: Compressor slowed - module running hot. This code is usually informational or minor. The safe checks below often clear it; call us if it keeps showing up.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Gree error code EU mean?

Everything keeps running but the compressor speed is cut because the inverter module is too hot.

Applies to: Gree Sapphire 9-24k (SAP..HP230V1A), Livo GEN4 30-36k (4LIV..HP230V1A), Vireo GEN3 9-24k (3VIR..HP115/230V1A)

Common causes of Gree code EU

  • Not enough thermal paste between the IPM module and heat sink
  • Heat sink screws loose
  • High load or poor airflow at the outdoor unit

A technician checks these and 1 other possible causes on site before replacing any part.

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Gree models that use code EU

3VIR09HP115V1A3VIR09HP230V1A3VIR12HP115V1A3VIR12HP230V1A3VIR18HP230V1A3VIR24HP230V1A4LIV30HP230V1AH4LIV36HP230V1AHSAP09HP230V1AHSAP12HP230V1AHSAP18HP230V1AHSAP24HP230V1AH

Other Gree Heat Pump codes

CodeMeaning
E6Indoor/outdoor communication fault
E7Mode conflict between indoor units (status)
E8High temperature / overload protection
E9Cold air prevention (status)
EdDrive IPM low temperature protection
EEEEPROM / memory chip fault
F0Low refrigerant / refrigerant blocked protection
F1Indoor room air sensor open or shorted
F2Indoor coil sensor open or shorted
F3Outdoor ambient sensor open or shorted
F4Outdoor coil (condenser middle) sensor open or shorted
F5Compressor discharge sensor open or shorted

All Gree Heat Pump error codes →

Gree code EU: homeowner questions

What does Gree code EU mean?

Compressor slowed - module running hot. Everything keeps running but the compressor speed is cut because the inverter module is too hot.

Is it safe to keep using my heat pump with code EU?

Usually yes. Code EU is normally minor, but if it keeps coming back have it checked.

Can I reset Gree code EU myself?

You can try one reset (power off for 30 seconds, then on). If Gree code EU comes back, the cause is still there and a licensed technician should check it.

Who can fix Gree code EU near me?

Aurora Star Tech Inc. repairs Gree heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: Gree Sapphire 9-12k (SAP09-12HP230V1A) service.pdf - section 9.1 Error Code List / 9.2 Procedure of Troubleshooting; Gree Sapphire 18-24k (SAP18-24HP230V1A) service.pdf - section 9.1 Error Code List / 9.2 Procedure of Troubleshooting; Gree Livo GEN4 30-36k (4LIV30-36HP230V1A) service.pdf - section 9.1 Error Code List / 9.2 Procedure of Troubleshooting; Gree Vireo GEN3 9-24k (3VIR..HP115-230V1A) service GREE_VIREOGEN3_SERVICE_090921.pdf - section 9.1 Error Code List / 9.2 Procedure of Troubleshooting. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977