Rinnai Tankless RSC clearances to combustibles
Rinnai Tankless RSC clearances to combustibles: reference table for the tankless water heater (SENSEI series): a quick-reference table with notes.
Rinnai Tankless RSC clearances to combustibles table
| Location | Clearance |
|---|---|
| Top | 2 in. (51 mm); 0 in. from vent components |
| Bottom/ground | 12 in. (305 mm) |
| Front | 0 in.; 24 in. (610 mm) service clearance |
| Back | 0 in. |
| Sides | 2 in. (51 mm); add 0.25 in. (6.35 mm) for recess box |
| Vent | 0 in. |
| Front exhaust (outdoor models) | 24 in. (610 mm) |
How to use the Rinnai Tankless RSC clearances to combustibles table
Find your exact model in the first column and read across the row. Values in the Rinnai Tankless RSC clearances to combustibles table are a summary for quick reference; the rating plate on the unit and the manufacturer's manual for your model always decide. If your model is not listed, or a value looks different from what you see on the unit, check the manual before changing anything.
Notes
- Same values apply to combustible and non-combustible surfaces.
Applies to: RSC199i, RSC160i (indoor); RSC199e, RSC160e (outdoor)
Rinnai models this applies to
Rinnai Tankless Water Heater error codes →
Source: Rinnai RSC SENSEI Installation and Operation Manual (100000773), Table 6 Clearances, p.22. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.