Updated · by Aurora Star Tech Inc.

Carrier Furnace Minimum clearances to combustibles: reference table for the furnace (59TP6A series): a quick-reference table with notes.

FurnaceClearances59TP6A

Carrier Furnace Minimum clearances to combustibles table

PositionClearance
Rear0 in. (0 mm)
Front (combustion air openings)1 in. (25 mm)
Front, required for service24 in. (610 mm) - check local code
All sides of supply plenum1 in. (25 mm) - check local code
Sides0 in. (0 mm)
Vent0 in. (0 mm)
Top of furnace1 in. (25 mm)

How to use the Carrier Furnace Minimum clearances to combustibles table

Find your exact model in the first column and read across the row. Values in the Carrier Furnace Minimum clearances to combustibles table are a summary for quick reference; the rating plate on the unit and the manufacturer's manual for your model always decide. If your model is not listed, or a value looks different from what you see on the unit, check the manual before changing anything.

Notes

  • Keep 1 in. from combustibles to supply duct for 36 in. horizontally from the furnace.
  • Do not set on carpet or combustible tile; downflow on combustible floor needs the accessory floor base unless on a matching coil casing.

Applies to: All 59TP6A sizes: 040-10, 040-12, 060-12, 060-14, 080-16, 080-20, 100-20, 120-22

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Carrier models this applies to

59TP6A040-1059TP6A040-1259TP6A060-1259TP6A060-1459TP6A080-1659TP6A080-2059TP6A100-2059TP6A120-22

Carrier Furnace error codes →

Source: Carrier 59TP6A Installation, Start-up, Operating and Service and Maintenance Instructions, Table 2 Minimum Clearances to Combustible Materials, p.6 (PDF p.9 of 96-page file). Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.