Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Lennox Error Code E408: Compressor contactor welded (Heat Pump)

Updated · by Aurora Star Tech Inc.

Lennox error code E408 on a heat pump means: Compressor contactor welded. It is also called Lennox diagnostic code E408.

High severityHeat Pump

Homeowner? What Lennox code E408 means for you

Call a technician Your heat pump is reporting: Compressor contactor welded. The heat pump has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Lennox error code E408 mean?

The compressor runs continuously. S30/S40 thermostat alert code 408 (shown as E408 on the unit control display).

Applies to: Lennox communicating heat pumps incl. variable-capacity inverter units in S30/S40 smart thermostat systems

Common causes of Lennox code E408

  • Welded contactor contacts
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Lennox models that use code E408

EL16KP1-018EL16KP1-024EL16KP1-030EL16KP1-036EL16KP1-042EL16KP1-048EL16KP1-060ML14KP1-018ML14KP1-024ML14KP1-030ML14KP1-036ML14KP1-042ML14KP1-048ML14KP1-060

Other Lennox Heat Pump codes

CodeMeaning
E402System pressure trip
E403Compressor short-cycling
E404Compressor rotor locked
E405Compressor open circuit
E406Compressor open start circuit
E407Compressor open run circuit
E409Outdoor control low 24 VAC
E410Open low pressure switch
E411Low pressure switch strikes lockout
E412Open high pressure switch
E413High pressure switch strikes lockout
E414High discharge line temperature

All Lennox Heat Pump error codes →

Lennox code E408: homeowner questions

What does Lennox code E408 mean?

Compressor contactor welded. The compressor runs continuously. S30/S40 thermostat alert code 408 (shown as E408 on the unit control display).

Is it safe to keep using my heat pump with code E408?

It depends on the cause. The heat pump has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset Lennox code E408 myself?

You can try one reset (power off for 30 seconds, then on). If Lennox code E408 comes back, the cause is still there and a licensed technician should check it.

Who can fix Lennox code E408 near me?

Aurora Star Tech Inc. repairs Lennox heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: Lennox Residential Communicating Systems Alert Code Guide (V2) 100017 (3/2023), Table 2 Alert Codes and Troubleshooting, p.29. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.