Lennox Furnace: Poor ignition or loud combustion resonance – Lennox SL280UHNV

Updated · by Aurora Star Tech Inc.

Poor ignition or loud combustion resonance - Lennox SL280UHNV on a Lennox furnace: SL280UHNV (ultra-low NOx air/gas burner) has trouble lighting or lights with a loud resonance. Hard ignition means too much combustion air (air orifice too large); resonance means too little air.

Homeowner with a furnace problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Lennox SL280UHNV 80% communicating furnaces: SL280UH060NV36A, SL280UH080NV48B, SL280UH080NV60C, SL280UH100NV60C

Common causes of poor ignition or loud combustion resonance - lennox sl280uhnv

  • Wrong or loose air orifice
  • Plugged air inlet screen
  • Vent/air intake restriction
  • Kinked, loose or plugged signal hoses to gas valve
  • Gas valve out of range
  • Low supply voltage or gas pressure (-05 models)

How to fix poor ignition or loud combustion resonance - lennox sl280uhnv: step by step

  1. 05 and later: confirm incoming voltage is 108-132 V and gas supply pressure is 5-14 in. w.c.; fix power or gas supply first.
  2. On -01 to -04 (not -040), make sure the inducer was slowed to 4300 RPM. If it wasn't, call your Lennox service rep.
  3. Check the air orifice (inside the gray coupling between the clamps): correct size per the orifice table, fully seated against the elbow, and air inlet screen clear.
  4. Check manifold pressure (-01 to -04 Table 18/19; -05 Table 23 0.0-0.10 in. w.c.). The gas valve is not adjustable - if manifold is out of range, replace the gas valve.
  5. If manifold is OK, check signal / system operating pressure (-05 Table 24). In range and still a problem: replace the air orifice; out of range: check vent/intake restriction, inlet screen and signal hoses.
  6. If pressure still wrong after fixing restrictions, replace the gas valve.
  7. Ignition problem after all checks: fit the 'difficulty igniting' (smaller) air orifice. -05 resonance: install Low Profile Combustion Air Intake Kit 25B23 (-01 to -04: fit the 'resonance' larger orifice).
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Lennox Furnace codes

Models

Lennox EL195UHNE

EL195UH040NE36BEL195UH060NE36BEL195UH080NE48CEL195UH100NE60C

EL296UHV

EL296UH045XV36BEL296UH070XV36BEL296UH090XV36CEL296UH090XV48CEL296UH090XV60CEL296UH110XV48CEL296UH110XV60CEL296UH135XV60D

Lennox ML180UHE

ML180UH045E36AKML180UH045XE36AKML180UH070E36AKML180UH070E36BKML180UH070XE36AKML180UH070XE36BKML180UH090E48BKML180UH090E60CKML180UH090XE48BKML180UH110E60CKML180UH110XE60CKML180UH135E60DK

Lennox SL280UHV

SL280UH060NV36ASL280UH070V36ASL280UH080NV48BSL280UH080NV60CSL280UH090V36BSL280UH090V48BSL280UH090V60CSL280UH100NV60CSL280UH110V60CSL280UH135V60D

Lennox SL297NV

SL297UH040NV36BSL297UH060NV36BSL297UH080NV48CSL297UH080NV60C

Source: Lennox SL280UHNV Unit Information Corp 1601-L8 (rev 04/2024), Figure 22 p.37 and Figure 26 p.41; Air Orifice Replacement Tables 20/25 p.36, 39. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Furnace Repair

647-657-2977