Lennox Furnace: Poor ignition or combustion resonance – Lennox EL195UHNE
Poor ignition or combustion resonance - Lennox EL195UHNE on a Lennox furnace: Burner is slow/hard to light or runs with a loud resonance (rumble/howl). On the EL195UHNE this is usually the air orifice in the air intake coupling, gas manifold pressure, or the signal pressure that drives the gas valve.
Applies to: EL195UHNE (EL195UH040/060/080/100NE)
Common causes of poor ignition or combustion resonance - lennox el195uhne
- Wrong or loose air orifice (oversized = hard ignition, undersized = resonance)
- Blocked air inlet screen
- Manifold pressure out of range
- Signal pressure out of range from vent/intake restriction, plugged drain, or kinked signal hoses
- Faulty gas valve
How to fix poor ignition or combustion resonance - lennox el195uhne: step by step
- Check the air orifice: correct part number for the size (Table 20), fully seated against the elbow, and the air inlet screen clear.
- Production orifices: 040 = 0.800 (16), 060 = 0.995 (14), 080 = 1.105 (12), 100 = 1.250 (06).
- Measure manifold pressure after 8 minutes of run time: natural gas 3.2-3.8 in. w.c. at 0-4500 ft. The valve is not adjustable - do not try to adjust it.
- If manifold pressure is in range but the problem remains, change the air orifice: for resonance use the larger (more air) orifice, for hard ignition the smaller (less air) orifice - see Table 20 catalog numbers.
- If manifold pressure is out of range, measure signal pressure (Table 19, e.g. 0.80-0.93 in. w.c. for 040 at 0-4500 ft). If signal is in range, replace the gas valve.
- If signal pressure is out of range, check vent/intake for restriction, plugged condensate drain, plugged inlet screen, and signal hoses for kinks or loose fit; fix and recheck manifold pressure - if still wrong, replace the gas valve.
- To reach the orifice: power and gas off, remove the black air pressure tube, loosen the gray coupling clamps (5/16 in. nut driver), remove the air intake coupling; reassemble fully seated and recheck pressures.
If the unit shows an error code, look it up: Lennox Furnace codes
Models
Lennox EL195UHNE
EL195UH040NE36BEL195UH060NE36BEL195UH080NE48CEL195UH100NE60C
EL296UHV
EL296UH045XV36BEL296UH070XV36BEL296UH090XV36CEL296UH090XV48CEL296UH090XV60CEL296UH110XV48CEL296UH110XV60CEL296UH135XV60D
Lennox ML180UHE
ML180UH045E36AKML180UH045XE36AKML180UH070E36AKML180UH070E36BKML180UH070XE36AKML180UH070XE36BKML180UH090E48BKML180UH090E60CKML180UH090XE48BKML180UH110E60CKML180UH110XE60CKML180UH135E60DK
Lennox SL280UHV
SL280UH060NV36ASL280UH070V36ASL280UH080NV48BSL280UH080NV60CSL280UH090V36BSL280UH090V48BSL280UH090V60CSL280UH100NV60CSL280UH110V60CSL280UH135V60D
Lennox SL297NV
SL297UH040NV36BSL297UH060NV36BSL297UH080NV48CSL297UH080NV60C
Source: Lennox EL195UHNE Unit Information Corp 1801-L1 (rev 04/2024), Manifold and signal pressure, Air orifice replacement, Table 19-20, Figure 57, p.41-44. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.