Rinnai EX22DT error codes list

CodeMeaningSeverity
11No ignitionHigh
14Overheat (fusible link)Critical
16Room overheat (above 104°F / 40°C)Medium
30Overheat temperature thermistor 2 open circuitMedium
31Room temperature thermistor open circuitMedium
32Room temperature thermistor short circuitMedium
33Overheat thermistor 1 open circuitMedium
34Overheat thermistor 1 short circuitMedium
35Overheat temperature thermistor 2 short circuitMedium
40Pressure sensor sensing tube failureMedium
49Pressure sensor breakdownMedium
53Abnormal spark sensedMedium
61Combustion fan faultMedium
62Convection fan faultMedium
70ON/OFF or Set Back switch faultMedium
71Solenoid valve failureMedium
72Flame rod failureMedium
73Communication errorMedium
99Flue blockedCritical

Rinnai EX22DT specs and setup data

All Rinnai Wall Furnace error codes →

Homeowner help: Furnace Not Turning On: What to Check

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.