Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Beckett Error Code Green light solid: Flame sensed (Boiler)

Updated · by Aurora Star Tech Inc.

Beckett error code Green light solid on a boiler means: Flame sensed. It is also called Beckett diagnostic code Green light solid.

Low severityBoilerBeckett NX

Homeowner? What Beckett code Green light solid means for you

Usually minor Your boiler is reporting: Flame sensed. This code is usually informational or minor. The safe checks below often clear it; call us if it keeps showing up.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Look at the pressure gauge on the boiler. If it reads much lower than usual or near zero, or water is leaking, call a technician.
  • Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
  • Check that the boiler gas valve is open (handle in line with the pipe).
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Beckett error code Green light solid mean?

Solid green is normal while the burner is running: the cad cell sees flame. If it is on while the burner is off in standby, the cad cell is seeing stray light.

Applies to: Beckett NX burner with GeniSys 7505 primary control on Weil-McLain Ultra Oil UO-3, UO-4, UO-5 (CV and DV)

Common causes of Beckett code Green light solid

  • Burner firing normally
  • In standby: light leaking onto the cad cell (burner cover off, sight port or room light)
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Other Beckett Boiler codes

CodeMeaning
Green light flashingRecycle - flame lost while running
Red light flashingSoft lockout - no flame proved
Red light solidRestricted (hard) lockout
Yellow light solidPump prime mode (or reset held 15 s)

All Beckett Boiler error codes →

Beckett code Green light solid: homeowner questions

What does Beckett code Green light solid mean?

Flame sensed. Solid green is normal while the burner is running: the cad cell sees flame. If it is on while the burner is off in standby, the cad cell is seeing stray light.

Is it safe to keep using my boiler with code Green light solid?

Usually yes. Code Green light solid is normally minor, but if it keeps coming back have it checked.

Can I reset Beckett code Green light solid myself?

You can try one reset (power off for 30 seconds, then on). If Beckett code Green light solid comes back, the cause is still there and a licensed technician should check it.

Who can fix Beckett code Green light solid near me?

Aurora Star Tech Inc. repairs Beckett boilers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Boiler Not Heating: What to Check

Troubleshooting guides

Source: Beckett NX Burner Manual for Weil-McLain Ultra Oil boilers (W-M 550-141-996/0321), Table 5 Status Lights p.13. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Boiler Repair

647-657-2977