Beckett Error Code Green light solid: Flame sensed (Boiler)
Beckett error code Green light solid on a boiler means: Flame sensed. It is also called Beckett diagnostic code Green light solid.
Homeowner? What Beckett code Green light solid means for you
Usually minor Your boiler is reporting: Flame sensed. This code is usually informational or minor. The safe checks below often clear it; call us if it keeps showing up.
Safe things you can check yourself
- Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
- Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
- Look at the pressure gauge on the boiler. If it reads much lower than usual or near zero, or water is leaking, call a technician.
- Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
- Check that the boiler gas valve is open (handle in line with the pipe).
- Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.
Call (647) 657-2977Book a service call
Licensed technicians serving Vaughan, Toronto and the GTA.
What does Beckett error code Green light solid mean?
Solid green is normal while the burner is running: the cad cell sees flame. If it is on while the burner is off in standby, the cad cell is seeing stray light.
Applies to: Beckett NX burner with GeniSys 7505 primary control on Weil-McLain Ultra Oil UO-3, UO-4, UO-5 (CV and DV)
Common causes of Beckett code Green light solid
- Burner firing normally
- In standby: light leaking onto the cad cell (burner cover off, sight port or room light)
Other Beckett Boiler codes
All Beckett Boiler error codes →
Beckett code Green light solid: homeowner questions
What does Beckett code Green light solid mean?
Flame sensed. Solid green is normal while the burner is running: the cad cell sees flame. If it is on while the burner is off in standby, the cad cell is seeing stray light.
Is it safe to keep using my boiler with code Green light solid?
Usually yes. Code Green light solid is normally minor, but if it keeps coming back have it checked.
Can I reset Beckett code Green light solid myself?
You can try one reset (power off for 30 seconds, then on). If Beckett code Green light solid comes back, the cause is still there and a licensed technician should check it.
Who can fix Beckett code Green light solid near me?
Aurora Star Tech Inc. repairs Beckett boilers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.
Homeowner help: Boiler Not Heating: What to Check
Troubleshooting guides
- Condensing/corrosion of conventional boiler All brands · Boiler
- No heat or some zones cold All brands · Boiler
- Noise All brands · Boiler
- Poor heat / circulation All brands · Boiler
- Relief valve weeps every cycle / pressure climbs All brands · Boiler
- Short cycling / wasted fuel All brands · Boiler
- Symptoms of air in system All brands · Boiler
- Uneven heating All brands · Boiler
Source: Beckett NX Burner Manual for Weil-McLain Ultra Oil boilers (W-M 550-141-996/0321), Table 5 Status Lights p.13. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.