Beckett Error Code Green light flashing: Recycle – flame lost while running (Boiler)
Beckett error code Green light flashing on a boiler means: Recycle - flame lost while running. It is also called Beckett diagnostic code Green light flashing.
Homeowner? What Beckett code Green light flashing means for you
Check, then call Your boiler is reporting: Recycle - flame lost while running. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.
Safe things you can check yourself
- Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
- Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
- Look at the pressure gauge on the boiler. If it reads much lower than usual or near zero, or water is leaking, call a technician.
- Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
- Check that the boiler gas valve is open (handle in line with the pipe).
- Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.
Call (647) 657-2977Book a service call
Licensed technicians serving Vaughan, Toronto and the GTA.
What does Beckett error code Green light flashing mean?
Flashing green means the flame dropped out during the run. The control shut the burner down and is waiting 60 seconds before it tries the ignition sequence again. If it keeps losing flame past the control's set time, it goes to hard lockout instead.
Applies to: Beckett NX burner with GeniSys 7505 primary control on Weil-McLain Ultra Oil UO-3, UO-4, UO-5 (CV and DV)
Common causes of Beckett code Green light flashing
- Air in the oil line or pump (flame pulses then drops)
- Partly plugged nozzle or filter
- Poor combustion setting or draft problem
A technician checks these and 2 other possible causes on site before replacing any part.
Other Beckett Boiler codes
| Code | Meaning |
|---|---|
| Green light solid | Flame sensed |
| Red light flashing | Soft lockout - no flame proved |
| Red light solid | Restricted (hard) lockout |
| Yellow light solid | Pump prime mode (or reset held 15 s) |
All Beckett Boiler error codes →
Beckett code Green light flashing: homeowner questions
What does Beckett code Green light flashing mean?
Recycle - flame lost while running. Flashing green means the flame dropped out during the run. The control shut the burner down and is waiting 60 seconds before it tries the ignition sequence again. If it keeps losing flame past the control's set time, it goes to hard…
Is it safe to keep using my boiler with code Green light flashing?
It depends on the cause. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.
Can I reset Beckett code Green light flashing myself?
You can try one reset (power off for 30 seconds, then on). If Beckett code Green light flashing comes back, the cause is still there and a licensed technician should check it.
Who can fix Beckett code Green light flashing near me?
Aurora Star Tech Inc. repairs Beckett boilers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.
Homeowner help: Boiler Not Heating: What to Check
Troubleshooting guides
- Condensing/corrosion of conventional boiler All brands · Boiler
- No heat or some zones cold All brands · Boiler
- Noise All brands · Boiler
- Poor heat / circulation All brands · Boiler
- Relief valve weeps every cycle / pressure climbs All brands · Boiler
- Short cycling / wasted fuel All brands · Boiler
- Symptoms of air in system All brands · Boiler
- Uneven heating All brands · Boiler
Source: Beckett NX Burner Manual for Weil-McLain Ultra Oil boilers (W-M 550-141-996/0321), Table 5 Status Lights p.13; Sequence of Operation (Recycle) p.12; cad cell note p.15. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.