Viessmann Boiler: Combustion air cover and room air operation
Combustion air cover and room air operation on a Viessmann boiler: The combustion air cover is not fitted at the factory on the concentric vent adaptor but ships with the boiler. Leaving it off can cause unintended room air dependent operation.
Applies to: Concentric vent installations
How to fix combustion air cover and room air operation: step by step
- Check the chosen venting configuration.
- Install the combustion air cover if the configuration requires it.
- For room air dependent operation, provide combustion and ventilation air per the single pipe venting section of the venting instructions.
If the unit shows an error code, look it up: Viessmann Boiler codes
Models
More commissioning tips for boiler
Source: Vitodens 100-W, B1HE/B1KE Combi Technical Data, p. 30. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.