Gas pipe sizing worked example on a Rinnai boiler: The manual example adds the boiler input (65,000 Btu/hr) to the additional appliance input (199,000 Btu/hr) for a total of 264,000 Btu/hr. Divide by the gas heating value (1,000 Btu/ft3) to get 264 CFH. At 264 CFH the pipe must be at least 3/4 in nominal size for 10 ft run.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Natural gas sizing worksheet

How to fix gas pipe sizing worked example: step by step

  1. Add all gas input in Btu/hr: boiler plus other appliances.
  2. Divide total input by the gas heating value (Btu/ft3) to get CFH.
  3. Pick the table for your gas type and pipe type, then find the size that meets the CFH at your run length.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Rinnai Boiler codes

More other tips for boiler

Source: Rinnai I-Series Plus IP060160C installation manual, p. 53. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Boiler Repair

647-657-2977