Navien Air Conditioner: Repairing the refrigerant circuit (R-454B flammable refrigerant)

Updated · by Aurora Star Tech Inc.

Repairing the refrigerant circuit (R-454B flammable refrigerant) on a Navien air conditioner: Follow this sequence before opening the refrigerant circuit for any repair. Use the required recovery equipment and handle the flammable refrigerant safely.

Homeowner with a air conditioner problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: NAA outdoor unit

How to fix repairing the refrigerant circuit (r-454b flammable refrigerant): step by step

  1. Recover the refrigerant with a recovery pump certified for flammable refrigerants.
  2. Purge the circuit with nitrogen.
  3. Evacuate the circuit to 1,500 microns.
  4. Open the circuit only by cutting or brazing.
  5. Break the vacuum with a nitrogen purge, keeping the vacuum pump outlet away from any ignition source.
  6. Replace the filter drier every time the refrigerant circuit is opened.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Navien Air Conditioner codes

More other tips for air conditioner

Source: Navien NAA air conditioner service manual, p. 19. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.