Navien Air Conditioner: Installation limits and pre-start checks
Installation limits and pre-start checks on a Navien air conditioner: Confirm the site and piping limits before starting the unit.
Applies to: NAA17V36-24K/36K and NAA17V60-48K/60K
How to fix installation limits and pre-start checks: step by step
- Confirm the site is no higher than 10,000 ft (3000 m) above sea level.
- Keep the maximum lineset at 100 ft and the maximum vertical lift at 50 ft.
- Add a trap if vertical lift is over 16 ft (see manual p. 16).
- Match the indoor unit to the correct TXV and approved AHRI-listed indoor match.
- Check that the vapor and liquid lines are the right size for the unit capacity.
- Locate the unit away from windows, patios, and decks to limit noise.
- Check that factory tubing on both units has not shifted in shipping and is not rubbing on other tubing or sheet metal.
- Check that TXV feeder tube wire ties are secure and tight.
If the unit shows an error code, look it up: Navien Air Conditioner codes
More commissioning tips for air conditioner
Source: Navien NAA air conditioner service manual, p. 11. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.