Updated · by Aurora Star Tech Inc.

Refrigerant pipe burial limits on a Viessmann heat pump: Do not bury more than 36 in. (914 mm) of refrigerant pipe. If any section is buried, it needs a 6 in. (152 mm) vertical rise to the outdoor unit valve connections. Longer buried runs let refrigerant migrate to the cold section during shutdown, which can cause slugging and compressor damage at start-up.

Homeowner with a heat pump problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: DLCLRC sizes 36K-58K refrigerant piping

How to fix refrigerant pipe burial limits: step by step

  1. Limit buried refrigerant pipe to 36 in. (914 mm).
  2. Provide a 6 in. (152 mm) vertical rise to the outdoor valve connections where any pipe is buried.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Viessmann Heat Pump codes

Models

06AAK09AAK12AAJ12AAK18AAK24AAK30AAKDLCLRCQ36AA3DLCLRCQ48AA3DLCLRCQ58AA3DLCURAQ18AA3DLCURAQ18AB3DLCURAQ24AA3DLCURAQ24AB3DLCURAQ30AA3DLCURAQ30AB3DLCURAQ36AA3DLCURAQ36AB3DLCURAQ48AA3DLCURAQ48AB3DLCURAQ60AA3DLCURAQ60AB3

More other tips for heat pump

Source: Viessmann DLCLRC service manual, p. 2 of 60. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.