Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Viessmann Heat Pump: Forced operation (TOUCH button)

Updated · by Aurora Star Tech Inc.

Forced operation (TOUCH button) on a Viessmann heat pump: Runs the unit in forced auto or forced cooling without the remote. General protections and remote control stay active.

Homeowner with a heat pump problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: DLCSRB indoor high-wall units

How to fix forced operation (touch button): step by step

  1. With the unit off, press TOUCH once to start FORCED AUTO at 75.2°F (24°C).
  2. Press TOUCH again within 5 seconds to start FORCED COOLING.
  3. In FORCED COOLING the compressor runs at F2 and the fan runs at breeze speed for 30 minutes, then the unit goes to AUTO at 75.2°F (24°C).
  4. Press TOUCH to turn the unit off from any forced mode.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Viessmann Heat Pump codes

Models

06AAK09AAK12AAJ12AAK18AAK24AAK30AAKDLCLRCQ36AA3DLCLRCQ48AA3DLCLRCQ58AA3DLCURAQ18AA3DLCURAQ18AB3DLCURAQ24AA3DLCURAQ24AB3DLCURAQ30AA3DLCURAQ30AB3DLCURAQ36AA3DLCURAQ36AB3DLCURAQ48AA3DLCURAQ48AB3DLCURAQ60AA3DLCURAQ60AB3

More service & test modes tips for heat pump

Source: DLCSRB Service Manual, p. 22. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977