Carrier Heat Pump: Flammable refrigerant: repair and handling rules
Flammable refrigerant: repair and handling rules on a Carrier heat pump: The system uses a flammable refrigerant. Only trained personnel holding the required certification should open the refrigerant circuit.
Applies to: R-flammable refrigerant systems
How to fix flammable refrigerant: repair and handling rules: step by step
- Do not puncture refrigerant tubing.
- Do not use means to speed defrosting or cleaning other than those the manufacturer recommends.
- Store the unit in a room with no continuously operating ignition sources.
- Use only leak detection equipment suitable for flammable refrigerants; do not use a halide torch or naked flame.
- Remove or put out all naked flames if a leak is suspected.
- Keep NO SMOKING signs displayed and a dry powder or CO2 extinguisher near the charging area when hot work is done.
- Work only in an open or adequately ventilated area before breaking into the system.
If the unit shows an error code, look it up: Carrier Heat Pump codes
Models
37MUHA37MURAD5FUAAH18AAKD5FUAAH24AAKD5FUAAH30AAKD5FUAAH36AAKD5FUAAH48AAKD5FUAAH60AAK
Source: D5FUAA Service Manual, p. 3-6. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.