Carrier Heat Pump: Electrical parts removal
Electrical parts removal on a Carrier heat pump: Procedure to remove the electrical parts in the indoor unit. Anti-static gloves must be worn.
Applies to: D5FCFAH indoor unit
How to fix electrical parts removal: step by step
- Remove 1 screw of the supporting board and remove the board.
- Remove the 2 screws of the electronic control box cover and remove the cover.
- Remove 2 screws and remove the refrigerant sensor.
- Remove the 2 screws of the electronic control box.
- Disconnect the connectors and remove the electronic control box.
- Release the 2 hooks and remove the main control board.
- Disconnect the connectors and remove 1 screw of the fan driver control board.
- Remove 1 screw and remove the reactor.
If the unit shows an error code, look it up: Carrier Heat Pump codes
Models
Source: D5FCFAH service manual, p. 54-55. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.