Carrier Air Handler: Return air and plenum sealing
Return air and plenum sealing on a Carrier air handler: There must be an airtight seal between the bottom of the air handler and the return air plenum. Return air must not be drawn from a room with a gas appliance, water heater or carbon monoxide-producing device such as a wood fireplace.
Applies to: All installations with return air plenum
How to fix return air and plenum sealing: step by step
- Seal the plenum-to-cabinet joint with fiberglass sealing strips, foil duct tape, caulking or an equal method.
- Confirm return air is not drawn from a room that contains a gas or CO-producing appliance.
- Apply sealant where wires, refrigerant pipes and condensate pipes enter the cabinet.
- Seal drain line holes with duct tape or flexible sealant so warm air cannot enter.
If the unit shows an error code, look it up: Carrier Air Handler codes
Models
45MUAAQ18XX345MUAAQ24XX345MUAAQ30XX345MUAAQ36XX345MUAAQ48XX345MUAAQ60XX3D5FUAA
More other tips for air handler
Source: D5FUAA installation instructions, p. 15, p. 16. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.