Updated · by Aurora Star Tech Inc.

Refrigerant piping buried underground on a Carrier air handler: Limits for buried refrigerant pipe.

Homeowner with a air handler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Refrigerant piping installation

How to fix refrigerant piping buried underground: step by step

  1. Do not bury more than 36 in. (914 mm) of refrigerant pipe.
  2. If any pipe is buried, provide a 6 in. (152 mm) vertical rise to the outdoor unit valve connections.
  3. Buried pipe that is too long can let refrigerant migrate and cause slugging and compressor damage at startup.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Carrier Air Handler codes

Models

45MUAAQ18XX345MUAAQ24XX345MUAAQ30XX345MUAAQ36XX345MUAAQ48XX345MUAAQ60XX3D5FUAA

More other tips for air handler

Source: D5FUAA Installation Instructions, p. 2. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.