Other: Air Handler tips (part 4 of 6)

Updated · by Aurora Star Tech Inc.

Short, practical technician tips on other for air handler. Check each one against the manual for your exact model before acting.

LED display behaviour

Carrier · D5FUHA with LED display

Normally the LED shows the current temperature setpoint. When a fault is active, it flashes the fault code quickly. The fault code table is in the troubleshooting section, not on these pages.

  1. If the display shows a setpoint, the unit is running normally.
  2. If the display flashes a code, look it up in the troubleshooting section's fault code table.

Location restrictions

Carrier · Indoor unit site selection

Do not install in areas with oil drilling or fracking, coastal salt air, caustic or corrosive gases, hot-spring gases, power fluctuations (such as factories), enclosed cabinets, strong electromagnetic fields, or where flammable materials or gas are stored. Avoid high-humidity rooms such as bathrooms and laundry rooms. Keep the unit at least 3 ft (1 m) from TVs and radios. Keep units with auxiliary electric heat at least 3 ft (1 m) from combustible materials.

  1. Pick a location that meets all listed restrictions.
  2. Keep the cables and unit at least 3-1/5 ft (1 m) from televisions and radios.
  3. Keep units with auxiliary heat 3 ft (1 m) from combustibles.

Main board jumpers and dip switch notes

Carrier · D5FUHA indoor main control board

Wiring diagram notes for the indoor main control board. Jumper and switch changes are only made for specific functions.

  1. Remove the short connector on JR1 when using the ON-OFF function.
  2. Remove the short connector on J7 when using the water-level switch function.
  3. Leave the other dip switches at their default OFF setting unless the manual calls for a change.
  4. Refer to the installation manual for the use of each dip switch.
  5. Power must be off before changing the ENC1 capacity dip switch.

Meaning of unit symbols

Carrier · D5FULA crossover evaporator coil, sizes 24K - 60K

Symbols on the indoor or outdoor unit mean: flammable refrigerant is used (risk of fire if leaked and ignited); read the operation manual; service personnel must handle the equipment with the installation manual; information is available in the operating or installation manual.

Metering devices

Carrier · DLFULA evaporator coil with outdoor unit

The outdoor unit uses an electronic metering device (EEV) in heating. The indoor evaporator coil uses a TXV in cooling.

Minimum line length and suction line insulation

Carrier · D5FSAA / D5FLAA with matching outdoor unit

Minimum refrigerant line length between indoor and outdoor units is 10 ft (3 m). The suction line must be insulated.

  1. Keep the line set at or above 10 ft (3 m).
  2. Insulate the suction line.
  3. Check the outdoor unit manual for allowed length and height difference.

Model number breakdown

Carrier · D5FUHA

D5 is the indoor unit, FU is unitary, H is air handler, Q is heat pump, 24/36/60 is nominal capacity (2, 3 or 5 ton), A is crossover, X is indoor unit, and K is 208/230-1-60 voltage (can be configured for 115 V).

OFF mode controller

Carrier · D5FS(L)AAH

When the controller is turned off, the unit turns off and stays off until the controller is turned back on.

Operating mode priority

Carrier · D5FUAAH

The unit has five modes: FAN Only, AUTO, HEATING (heat pumps only), COOLING, and DEHUMIDIFICATION (DRY). HEATING has priority, and simultaneous heating and cooling is not allowed. DRY dehumidifies but does not replace a dehumidifier.

Outdoor unit power below freezing

Carrier · Outdoor units with auxiliary electric heater

Units with an auxiliary electric heater on the outdoor unit need protection in cold weather.

  1. When outdoor temperature is below 0°C (32°F), keep the outdoor unit powered at all times to prevent equipment damage.

Outdoor-to-indoor signal wire

Carrier · D5FULA

Signal wire choice for communication between the indoor and outdoor units.

  1. Use shielded 16 AWG wire for the outdoor/indoor signal wire to reduce noise, especially in high EMF areas.
  2. Use the gauge shown in Fig. 24 for the signal wire line.

Parts, access and qualified service

Carrier · All service work

Who may service the unit and which parts may be fitted.

  1. Only trained, qualified installers and service technicians should install, start up and service the unit.
  2. Use only the included accessories and manufacturer-specified parts.
  3. On units with wireless network function, USB device access and replacement must be done by professional staff.
  4. Relocating the unit requires experienced service technicians to disconnect and reinstall it.

Piping joints and burial limits

Carrier · Field refrigerant piping

Only brazed or welded joints may be used on the indoor side. Detachable joints are not allowed there. Do not bury more than 36 in. (914 mm) of refrigerant pipe. Any buried section must rise 6 in. (152 mm) vertically to the outdoor valve connections. Pipe runs must be kept as short as practical and protected from physical damage.

  1. Use only brazed or welded joints on the indoor side.
  2. Limit buried refrigerant pipe to 36 in. (914 mm).
  3. Provide a 6 in. (152 mm) vertical rise to the outdoor valves from any buried section.
  4. Make sure mechanical connections are accessible for service.

Power and disconnect requirements

Carrier · Electrical installation

Main power is supplied to the outdoor unit. Disconnecting the outdoor unit also removes power from the indoor unit. A separate disconnect may be required for the indoor unit, and the auxiliary heater needs its own power.

  1. Size the wires and disconnect using outdoor unit MCA and MOCP.
  2. Provide a disconnect within sight and readily accessible from the system.
  3. Provide separate power for any auxiliary electric heater.

Power wiring for 115 V and 208/230 V

Carrier · D5FUHA main board power input

Terminal block wiring depends on supply voltage.

  1. For 208 V or 230 V supply, connect L1 and L2.
  2. For 115 V supply, connect L1 and L2, with L2 used as neutral (N).
  3. Use only the specified wire and make sure the product is grounded.
  4. Clamp cables securely and make sure the control board cover closes properly.

Purging and breaking vacuum on flammable refrigerant systems

Carrier · Flammable refrigerant systems

Purging rules for systems with flammable refrigerant.

  1. Never use compressed air or oxygen to purge the system.
  2. Break the vacuum with oxygen-free nitrogen and fill to working pressure, then vent to atmosphere.
  3. Repeat until no refrigerant remains in the system.
  4. Vent the final nitrogen charge to atmospheric pressure before work starts.
  5. Keep the vacuum pump outlet away from ignition sources and make sure there is ventilation.

Purging with oxygen-free nitrogen

Carrier · Flammable refrigerant systems

Compressed air and oxygen must never be used to purge the system. Purge with oxygen-free nitrogen by breaking vacuum, filling to working pressure, venting to atmosphere, then pulling down to vacuum. Repeat until no refrigerant remains. Vent to atmospheric pressure before opening the circuit.

  1. Break the vacuum with oxygen-free nitrogen and fill to working pressure.
  2. Vent to atmosphere.
  3. Pull down to vacuum again.
  4. Repeat until no refrigerant remains.
  5. Vent to atmospheric pressure before work starts.

Qualification for refrigerant circuit work

Carrier · Refrigerant circuit service

Only persons with a current valid certificate from an accredited assessment authority may work on or open a refrigerant circuit. Other skilled helpers must work under the supervision of a competent person.

  1. Confirm the technician holds a current valid refrigerant handling certificate.
  2. Have helpers work under supervision of a competent person.

Recommended spacing between mounted indoor units

Carrier · Indoor air handler

Spacing between units is shown in figures 9 and 10 (horizontal and vertical).

  1. Mount the indoor unit so the spacing matches the horizontal (Fig. 9) or vertical (Fig. 10) drawing on page 16.
  2. Use the figure dimensions; the numbers are not printed in the text.

Record every INQUIRY and SERVICE change

Carrier · D5FUHA remote controller

The remote and indoor unit do not display changed values after exit, and the code shows its default (0) on the next entry. Without a written record, the current setting cannot be confirmed.

  1. Write down each code number and the value set during the visit.
  2. If the previous value is unknown, press DOWN to the maximum change range of -6, then press UP back to 0, and set the new value.
  3. Keep the record with the job documents.

Recovery cylinder and refrigerant handling limits

Carrier · D5FULA crossover evaporator coil with flammable refrigerant

Recovery cylinders must be designated for the recovered refrigerant and labeled for it. Do not fill over 80 percent of liquid volume or exceed cylinder maximum pressure. Do not mix refrigerants. Do not recharge recovered refrigerant unless it has been cleaned and checked.

  1. Confirm the cylinder has a pressure-relief valve and working shut-off valves.
  2. Weigh the cylinder on calibrated scales during recovery.

Recovery cylinder filling limits

Carrier · Refrigerant recovery

Do not fill recovery cylinders above 80% of volume by liquid, and never exceed the cylinder's maximum working pressure, even briefly. Do not mix refrigerants in recovery units or cylinders. Recovered refrigerant must not be recharged into another system unless cleaned and checked.

  1. Fill cylinders to no more than 80% liquid volume.
  2. Keep cylinder pressure below its maximum working pressure.
  3. Do not mix refrigerants.
  4. Do not recharge recovered refrigerant unless it has been cleaned and checked.

Refrigerant detection sensor access and replacement

Carrier · D5FULA indoor coil

The R454B refrigerant detection sensor sits in the unit near the coil. The removable cover plate gives access for inspection and repair. Only sensors specified by the manufacturer may be used, and the unit must stay powered except for service.

  1. Turn off power before removing the cover plate.
  2. Remove the removable cover plate for inspection and repair.
  3. Check the T2 sensor wire and the R454B sensor wire are connected.
  4. Replace the sensor only with a manufacturer-specified part.
  5. Keep the unit powered except during service.

Refrigerant joint leak testing

Carrier · Refrigerant piping joints

Joints must be tested with detection equipment rated to find 5 g/year of refrigerant or better, with the system at standstill and under operation or pressure. Detachable joints are not allowed on the indoor side. Brazed or welded joints are allowed.

  1. Test all joints with a detector rated 5 g/year or better after installation.
  2. Do not use detachable joints on the indoor unit side.
  3. Use brazed or welded joints on the indoor side.

Refrigerant line burial limits

Carrier · D5FULA refrigerant line runs

Refrigerant pipe must not be buried more than 36 in. If any section is buried, the line must rise at least 6 in to the outdoor unit valve connections. Too much buried line can let refrigerant move into the cold section and cause slugging or compressor damage at startup.

  1. Keep buried sections within 36 in.
  2. Provide a 6 in vertical rise to the outdoor valve connections for any buried section.

Refrigerant piping buried underground

Carrier · Refrigerant piping installation

Limits for buried refrigerant pipe.

  1. Do not bury more than 36 in. (914 mm) of refrigerant pipe.
  2. If any pipe is buried, provide a 6 in. (152 mm) vertical rise to the outdoor unit valve connections.
  3. Buried pipe that is too long can let refrigerant migrate and cause slugging and compressor damage at startup.

Refrigerant safety during piping work

Carrier · D5FSAA / D5FLAA with R-410A style line set

Refrigerant leaks can cause oxygen-deficiency hazards in small rooms. Contamination from air, dust, moisture or foreign material can reduce capacity, raise high-side pressure, and cause explosion or injury.

  1. If the system is in a small room, take steps so refrigerant concentration cannot exceed the safety limit during a leak.
  2. Keep air, dust, moisture and foreign material out of the refrigerant circuit during installation.
  3. Ventilate the area right away if a refrigerant leak happens during installation.
  4. Confirm there are no leaks after the installation is complete.
  5. All field piping must be done by a licensed technician to local and national code.

Refrigerant tubing and replacement parts

Carrier · D5FUHAQ units

Safety reminders for field work on the refrigerant side.

  1. Do not puncture refrigerant tubing.
  2. Use only manufacturer-approved accessories and replacement parts, or the warranty and safety may be affected.
  3. Have a qualified installer or service agency make any modifications using factory-authorized kits or accessories.

Remote battery care

Carrier · Wireless remote RG10F8(2)/BGEFU1

Battery type and replacement rules for the wireless remote.

  1. Use two AAA 1.5V alkaline batteries. Do not mix old and new or different battery types.
  2. Average battery life under normal use is about 6 months.
  3. Replace batteries when the indoor unit no longer gives an audible beep or the Transmission Indicator fails to light.
  4. Remove the batteries if the remote will not be used for several weeks, to avoid leakage damage.
  5. Follow the polarity marks inside the battery compartment.

Remote battery type and life

Carrier · Wireless remote

The remote uses two AAA 1.5 V alkaline batteries. Average life is about 6 months. Remove the batteries if the remote will not be used for several weeks to avoid leakage damage.

  1. Use two new AAA 1.5 V alkaline batteries, matching the polarity marks.
  2. Do not mix old and new batteries or different battery types.
  3. Remove the batteries if the remote will be unused for several weeks.
  4. Replace the batteries when the unit does not beep on command or the transmission indicator fails to light.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.