Carrier Air Handler: Refrigerant line burial limits

Updated · by Aurora Star Tech Inc.

Refrigerant line burial limits on a Carrier air handler: Refrigerant pipe must not be buried more than 36 in. If any section is buried, the line must rise at least 6 in to the outdoor unit valve connections. Too much buried line can let refrigerant move into the cold section and cause slugging or compressor damage at startup.

Homeowner with a air handler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: D5FULA refrigerant line runs

How to fix refrigerant line burial limits: step by step

  1. Keep buried sections within 36 in.
  2. Provide a 6 in vertical rise to the outdoor valve connections for any buried section.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Carrier Air Handler codes

More other tips for air handler

Source: Carrier D5FULA installation instructions, p. 23. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.