Updated · by Aurora Star Tech Inc.

Purging with oxygen-free nitrogen on a Carrier air handler: Compressed air and oxygen must never be used to purge the system. Purge with oxygen-free nitrogen by breaking vacuum, filling to working pressure, venting to atmosphere, then pulling down to vacuum. Repeat until no refrigerant remains. Vent to atmospheric pressure before opening the circuit.

Homeowner with a air handler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Flammable refrigerant systems

How to fix purging with oxygen-free nitrogen: step by step

  1. Break the vacuum with oxygen-free nitrogen and fill to working pressure.
  2. Vent to atmosphere.
  3. Pull down to vacuum again.
  4. Repeat until no refrigerant remains.
  5. Vent to atmospheric pressure before work starts.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Carrier Air Handler codes

Models

D5FUHAH24AAKD5FUHAH36AAKD5FUHAH60AAKEHKMD05KNEHKMD08KNEHKMD10KNEHKMD15KNEHKMD20KNEHKMD25KN

More other tips for air handler

Source: Carrier D5FUHA service manual, p. 6. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.